Literature DB >> 957753

Arterial prosthesis of microporous expanded polytetrafluoroethylene for construction of aorta-pulmonary shunts.

A B Gazzaniga, J J Lamberti, R D Siewers, D R Sperling, W R Dietrick, R A Arcilla, R L Replogle.   

Abstract

A new arterial prosthesis made of polytetrafluoroethylene (OTFE) was evaluated in 10 infants with complex cyanotic congenital heart disease. All grafts used were 4 mm. in diameter and varied in length from 0.8 to 6 cm. The grafts were anastomosed to the main pulmonary artery or its bifurcation in 8 infants and to the right and left pulmonary arteries in one each. There were two early deaths, one of which was related to shunt failure. The advantages of a shunt to the main pulmonary artery are obvious, and the intraoperative procedure is facilitated with the prosthesis. Follow-up averages 9 months in the 8 survivors, and the patients have nearly doubled their preoperative weight. A shunt murmur is present in each case and the children have mild-to-moderate cyanosis at rest. Repeat aortograms in 2 patients, 8 and 10 months postoperatively, show a smooth graft without luminal narrowing. The aortic oxygen saturations were 73 per cent. The PTFE graft and/or anastomoses will not grow with the growth of the child and therefore may not accommodate growth by increased flow. This may prove to be a limiting factor in its long-term use in fants. We reserve the use of these grafts for infants with complex cyanotic defects undergoing emergency surgery or in older children in whom a conventional shunt is not possible or a previous shunt has failed.

Entities:  

Mesh:

Substances:

Year:  1976        PMID: 957753

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  9 in total

Review 1.  Surgical management of congenital heart defects: current trends.

Authors:  P S Chopra; P S Rao
Journal:  Indian J Pediatr       Date:  1991 Sep-Oct       Impact factor: 1.967

2.  Present status of surgery in congenital heart disease.

Authors:  P S Rao
Journal:  Indian J Pediatr       Date:  1981 May-Jun       Impact factor: 1.967

3.  Use of saphenous vein allografts for aortopulmonary artery anastomoses in neonates with complex cyanotic congenital heart disease.

Authors:  D Danilowicz; R G Ishmael; E F Doyle; O W Isom; S B Colvin; M A Greco
Journal:  Pediatr Cardiol       Date:  1984 Jan-Mar       Impact factor: 1.655

4.  Maintaining patency of the ductus-arteriosus for palliation of cyanotic congenital cardiac malformations. The use of prostaglandin E1 and formaldehyde infiltration of the ductal wall.

Authors:  J Hatem; R M Sade; J K Upshur; A R Hohn
Journal:  Ann Surg       Date:  1980-07       Impact factor: 12.969

5.  Preliminary experience with GORE-TEX grafting for right ventricle-pulmonary artery conduits.

Authors:  J E Molina
Journal:  Tex Heart Inst J       Date:  1986-03

6.  Aneurysm of the right ventricular outflow tract: a complication of aorta-main pulmonary (central) shunt.

Authors:  E Welch; I Zabaleta; R Fojaco; R Perryman
Journal:  Pediatr Cardiol       Date:  1991-10       Impact factor: 1.655

7.  Infection of modified Blalock shunts.

Authors:  J S Carvalho; P Belcher; W B Knight
Journal:  Br Heart J       Date:  1987-09

8.  Experience with the modified Blalock-Taussig operation using polytetrafluoroethylene (Impra) grafts.

Authors:  P H Kay; A Capuani; R Franks; C Lincoln
Journal:  Br Heart J       Date:  1983-04

9.  Septic involvement of polytetrafluoroethylene (PTFE) anastomoses producing false aneurysms: diagnosis and problems related to management.

Authors:  C N Monarrez; R F Montalvo; V R Conti; D W Sapire
Journal:  Pediatr Cardiol       Date:  1984       Impact factor: 1.655

  9 in total