Literature DB >> 9576318

Evaluation of the effectiveness of a technique to prevent screw loosening.

P P Binon1.   

Abstract

STATEMENT OF PROBLEM: Abutment screw loosening of single and multiple fixed partial dentures attached to external hexagonal implants is commonly encountered.
PURPOSE: A technique that has been reported to prevent abutment screw loosening was tested with cyclic loading to determine its effectiveness.
MATERIAL AND METHODS: A sample using identical components and test protocol, with the abutment screw tightened to 20 Ncm, was used as control.
RESULTS: On the basis of the data obtained, the recommended technique does not increase resistance to screw loosening. The control sample sustained a mean number of cycles to screw loosening of more than twice that of the technique evaluated.

Mesh:

Substances:

Year:  1998        PMID: 9576318     DOI: 10.1016/s0022-3913(98)70157-x

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  6 in total

1.  Loosening torque of Universal Abutment screws after cyclic loading: influence of tightening technique and screw coating.

Authors:  Atais Bacchi; Alexandre Regalin; Claudia Lopes Brilhante Bhering; Rodrigo Alessandretti; Aloisio Oro Spazzin
Journal:  J Adv Prosthodont       Date:  2015-10-28       Impact factor: 1.904

2.  Evaluation of Micromovements and Stresses around Single Wide-Diameter and Double Implants for Replacing Mandibular Molar: A Three-Dimensional FEA.

Authors:  Shrikar R Desai; I Karthikeyan; Rika Singh
Journal:  ISRN Dent       Date:  2012-03-07

3.  Stability of the prosthetic screws of three types of craniofacial prostheses retention systems.

Authors:  Antonio Gabriel Lanata-Flores; Eder Alberto Sigua-Rodriguez; Douglas Rangel Goulart; Veber Luiz Bomfim-Azevedo; Sergio Olate; José Ricardo de Albergaria-Barbosa
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2016-12-27

4.  Salvage of fractured abutment screw by transfer cap screw replacement (original study).

Authors:  Rawaa Y Al-Rawee; Fatima A Mohammad; Bashar A Tawfeeq
Journal:  Clin Case Rep       Date:  2019-05-10

5.  Evaluation of the accuracy and related factors of the mechanical torque-limiting device for dental implants.

Authors:  Mahmood Kazemi; Ahmad Rohanian; Abbas Monzavi; Mohammad Sadegh Nazari
Journal:  J Dent (Tehran)       Date:  2013-03-31

6.  3D finite element analysis of immediate loading of single wide versus double implants for replacing mandibular molar.

Authors:  Shrikar R Desai; I Karthikeyan; Reetika Gaddale
Journal:  J Indian Soc Periodontol       Date:  2013-11
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.