Literature DB >> 9575928

Dissociation between volume blood flow and laser-Doppler signal from rat muscle during changes in vascular tone.

L V Kuznetsova1, N Tomasek, G H Sigurdsson, A Banic, D Erni, A M Wheatley.   

Abstract

Although the laser-Doppler flowmetry (LDF) signal from skeletal muscle has been shown to provide a good measure of blood flow under some conditions, its behavior during administration of vasoactive substances has never been addressed. The aims of this study were to compare 1) changes in LDF signal with those in total muscle blood flow measured with radioactive microspheres after ganglionic blockade (chlorisondamine) and during administration of angiotensin II (ANG II), phenylephrine (PE), and isoproterenol (Iso) and 2) changes in vascular resistance estimated by the two techniques. The LDF signal from the biceps femoris muscle was investigated in anesthetized male Wistar rats. Ganglionic blockade led to a significant (P < 0.05) fall in mean arterial pressure (MAP) [medians (lower, upper quartiles): 78 (72, 83) vs. 127 (114, 138) mmHg under basal conditions], muscle blood flow (MBF, microsphere technique; 61%), and the LDF signal (29%). Muscle vascular resistance (MVR = MAP/MBF) was increased (64%, P < 0.05), but vascular resistance estimated as MAP/LDF signal (MVRLDF) was unchanged. During ANG II and PE infusions, MAP rose (P < 0.05) to 178 (155, 194) and 127 (124, 142) mmHg, respectively; MBF did not change compared with the preinfusion (postganglionic blockade) level and remained significantly (P < 0.05) lower than baseline, whereas the LDF signal increased up to a level not different from baseline. MVR rose and was significantly (P < 0.05) higher than baseline, whereas MVRLDF did not differ significantly from baseline. During Iso infusion, MAP fell [58 (56, 60) vs. 94 (92, 102) mmHg, P < 0.05], the LDF signal was reduced (49%, P < 0.05) despite a large increase in MBF (139%, P < 0.05), and MVR fell (74%, P < 0.05), whereas MVRLDF did not change vs. preinfusion level. Our results suggest that 1) changes in the LDF signal from muscle may not correlate with changes in total muscle blood flow measured by the microsphere technique during infusion of vasoactive substances and 2) the use of LDF data for estimation of MVR during changes in vascular tone in rat skeletal muscle is probably not appropriate.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9575928     DOI: 10.1152/ajpheart.1998.274.4.H1248

Source DB:  PubMed          Journal:  Am J Physiol        ISSN: 0002-9513


  5 in total

1.  MRI of blood flow of the human retina.

Authors:  Qi Peng; Yi Zhang; Oscar San Emeterio Nateras; Matthias J P van Osch; Timothy Q Duong
Journal:  Magn Reson Med       Date:  2011-02-24       Impact factor: 4.668

2.  Blood flow after exercise-induced muscle damage.

Authors:  Noelle M Selkow; Daniel C Herman; Zhenqi Liu; Jay Hertel; Joseph M Hart; Susan A Saliba
Journal:  J Athl Train       Date:  2015-02-06       Impact factor: 2.860

3.  Blood flow magnetic resonance imaging of retinal degeneration.

Authors:  Yingxia Li; Haiying Cheng; Qiang Shen; Moon Kim; Peter M Thule; Darin E Olson; Machelle T Pardue; Timothy Q Duong
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-10-24       Impact factor: 4.799

4.  Blood-flow magnetic resonance imaging of the retina.

Authors:  Yingxia Li; Haiying Cheng; Timothy Q Duong
Journal:  Neuroimage       Date:  2007-11-01       Impact factor: 6.556

5.  Vasopressin in septic shock: effects on pancreatic, renal, and hepatic blood flow.

Authors:  Vladimir Krejci; Luzius B Hiltebrand; Stephan M Jakob; Jukka Takala; Gisli H Sigurdsson
Journal:  Crit Care       Date:  2007       Impact factor: 9.097

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.