Literature DB >> 9572525

Comparison of frequency-distance relationship and Gaussian-diffusion-based methods of compensation for distance-dependent spatial resolution in SPECT imaging.

V Kohli1, M A King, S J Glick, T S Pan.   

Abstract

The goal of this investigation was to compare resolution recovery versus noise level of two methods for compensation of distance-dependent resolution (DDR) in SPECT imaging. The two methods of compensation were restoration filtering based on the frequency-distance relationship (FDR) prior to iterative reconstruction, and modelling DDR in the projector/backprojector pair employed in iterative reconstruction. FDR restoration filtering was computationally faster than modelling the detector response in iterative reconstruction. Using Gaussian diffusion to model the detector response in iterative reconstruction sped up the process by a factor of 2.5 over frequency domain filtering in the projector/backprojector pair. Gaussian diffusion modelling resulted in a better resolution versus noise tradeoff than either FDR restoration filtering or solely modelling attenuation in the projector/backprojector pair of iterative reconstruction. For the pixel size investigated herein (0.317 cm), accounting for DDR in the projector/backprojector pair by Gaussian diffusion, or by applying a blurring function based on the distance from the face of the collimator at each distance, resulted in very similar resolution recovery and slice noise level.

Mesh:

Year:  1998        PMID: 9572525     DOI: 10.1088/0031-9155/43/4/029

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  7 in total

1.  Dosimetry for (177)Lu-DKFZ-PSMA-617: a new radiopharmaceutical for the treatment of metastatic prostate cancer.

Authors:  Andreas Delker; Wolfgang Peter Fendler; Clemens Kratochwil; Anika Brunegraf; Astrid Gosewisch; Franz Josef Gildehaus; Stefan Tritschler; Christian Georg Stief; Klaus Kopka; Uwe Haberkorn; Peter Bartenstein; Guido Böning
Journal:  Eur J Nucl Med Mol Imaging       Date:  2015-08-29       Impact factor: 9.236

2.  Uniform attenuation correction using the frequency-distance principle.

Authors:  Gengsheng L Zeng
Journal:  Med Phys       Date:  2007-11       Impact factor: 4.071

3.  System matrix modelling of externally tracked motion.

Authors:  Arman Rahmim; Ju-Chieh Cheng; Katie Dinelle; Mikhail Shilov; W Paul Segars; Olivier G Rousset; Benjamin M W Tsui; Dean F Wong; Vesna Sossi
Journal:  Nucl Med Commun       Date:  2008-06       Impact factor: 1.690

Review 4.  Absolute quantification in SPECT.

Authors:  Philipp Ritt; Hans Vija; Joachim Hornegger; Torsten Kuwert
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-04-12       Impact factor: 9.236

5.  Compensating for Non-Stationary Blurring by Further Blurring and Deconvolution.

Authors:  Gengsheng L Zeng
Journal:  Int J Imaging Syst Technol       Date:  2009-09-01       Impact factor: 2.000

6.  Quantitative performance of advanced resolution recovery strategies on SPECT images: evaluation with use of digital phantom models.

Authors:  Hideo Onishi; Nobutoku Motomura; Koichi Fujino; Takahiro Natsume; Yasuhiro Haramoto
Journal:  Radiol Phys Technol       Date:  2012-07-13

7.  Investigation of Collimator Influential Parameter on SPECT Image Quality: a Monte Carlo Study.

Authors:  Sh Banari Bahnamiri
Journal:  J Biomed Phys Eng       Date:  2015-03-04
  7 in total