Literature DB >> 9572421

Factors influencing human sperm kinematic measurements by the Celltrak computer-assisted sperm analysis system.

M Kraemer1, C Fillion, B Martin-Pont, J Auger.   

Abstract

This study examines the effect of varying several factors, both extrinsic and technology-dependent, on the reconstruction of human sperm trajectories and the derived kinematic measurements using videotapes and the Motion Analysis Celltrak/S instrument. In semen samples from normal healthy men, curvilinear (VCL) and straight line velocities (VSL) were found to increase 1.5-fold, and linearity (LIN) of trajectories and amplitude of lateral head displacement (ALH) increased 1.25-fold when the temperature of analysis was raised from 24 to 37 degrees C. Only VCL and VSL were found to increase significantly between 24 and 37 degrees C for sperm samples selected by Percoll gradient and incubated in a capacitating medium. An analysis chamber of 20 microm depth was found to be adequate for seminal sperm samples while for Percoll-selected sperm samples the analysis in a 50 microm depth provided the highest proportions of spermatozoa with the highest VCL and the largest ALH. The grey level detection threshold required careful adjustment: using a threshold lower than the optimal threshold produced spurious sperm trajectories for seminal sperm samples and rejected some trajectories for Percoll-selected sperm samples. Definition of the appropriate frame rate and maximum burst speed was critical for valid trajectory reconstruction and therefore adequate derived kinematic measurements. Optimal values of these parameters were found to be 30 Hz and 400 microm/s for seminal spermatozoa and 60 Hz and 700 microm/s for selected spermatozoa. The optimal values of 'ALH path-smoothing factor' used to calculate average path and ALH were 5-10 points for seminal spermatozoa analysed at 30 Hz and 15-20 points for selected spermatozoa analysed at 60 Hz. We propose a set of standard conditions for reliable kinematic analysis of human spermatozoa using the Celltrak/S system.

Entities:  

Mesh:

Year:  1998        PMID: 9572421     DOI: 10.1093/humrep/13.3.611

Source DB:  PubMed          Journal:  Hum Reprod        ISSN: 0268-1161            Impact factor:   6.918


  3 in total

1.  A Sperm Quality Detection System Based on Microfluidic Chip and Micro-Imaging System.

Authors:  Xiaoqing Pan; Kang Gao; Ning Yang; Yafei Wang; Xiaodong Zhang; Le Shao; Pin Zhai; Feng Qin; Xia Zhang; Jian Li; Xinglong Wang; Jie Yang
Journal:  Front Vet Sci       Date:  2022-06-30

2.  Semen preparation techniques in intrauterine insemination: A comparison of non-temperature and temperature controlled centrifugation in cases of unexplained infertility.

Authors:  Priya Selvaraj; Kamala Selvaraj; S Kalaichelvi; R Mahalakshmi
Journal:  J Hum Reprod Sci       Date:  2013-10

3.  Effects of diluting medium and holding time on sperm motility analysis by CASA in ram.

Authors:  Somayeh Mostafapor; Farhad Farrokhi Ardebili
Journal:  Vet Res Forum       Date:  2014       Impact factor: 1.054

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.