Literature DB >> 9572223

Intrapartum sonography and persistent occiput posterior position: a study of 408 deliveries.

M Gardberg1, E Laakkonen, M Sälevaara.   

Abstract

OBJECTIVE: To use intrapartum sonography as a tool to investigate the development of the persistent occiput posterior position during labor, as well as to identify parameters correlating with the outcome of labor.
METHODS: A prospective study of 408 women in labor after 37 weeks' gestation with a singleton fetus in a vertex position using sonography at the onset of labor was performed. Fetal position, placental location, and maternal BMI (body mass index) were recorded. Outcome of labor was monitored for all relevant parameters.
RESULTS: Most (68%) of persistent occiput posterior positions develop through a malrotation during labor from an initially occipitoanterior position. Only 32% of persistent cases were occipitoposterior (dorsoposterior) at the onset of labor; operative interventions were required in 87.5% of these. Of the 61 (15%) occipitoposterior positions at the onset of labor, 53 (87%) rotated into an occiput anterior position. Persistent occiput posterior position was more common in the initially occipitoposterior group (P < 0.01, Fisher exact test), and posterior placental locations were fewer (z test, P = 0.05). Also, operative deliveries were more common in the group remaining occipitoposterior throughout labor (P < .01, Fisher exact test). A higher maternal BMI correlated with neonatal weight (P < .01, Pearson correlation), an increase in operative deliveries (P = .032, Pearson correlation), lower Apgar scores at 1 minute (P = .02, Spearman correlation), and increase in posterior placental locations (P = .037, two-tailed t test).
CONCLUSION: In most cases, persistent occiput posterior position develops through a malrotation and only in a little more than one-third of cases through absence of rotation from an initially occipitoposterior position. Higher maternal BMI correlates with higher fetal weight, increased operative deliveries, lower Apgar scores at 1 minute, and posterior placental locations. Intrapartum sonography proved to be useful in investigating the development of the persistent occipitoposterior position.

Entities:  

Mesh:

Year:  1998        PMID: 9572223     DOI: 10.1016/s0029-7844(98)00074-x

Source DB:  PubMed          Journal:  Obstet Gynecol        ISSN: 0029-7844            Impact factor:   7.661


  15 in total

1.  Dynamic Changes in the Myometrium during the Third Stage of Labor, Evaluated Using Two-Dimensional Ultrasound, in Women with Normal and Abnormal Third Stage of Labor and in Women with Obstetric Complications.

Authors:  Manasi Patwardhan; Edgar Hernandez-Andrade; Hyunyoung Ahn; Steven J Korzeniewski; Alyse Schwartz; Sonia S Hassan; Roberto Romero
Journal:  Gynecol Obstet Invest       Date:  2015-01-28       Impact factor: 2.031

Review 2.  Maternal postures for fetal malposition in labour for improving the health of mothers and their infants.

Authors:  Jennifer A Barrowclough; Luling Lin; Bridget Kool; G Justus Hofmeyr; Caroline A Crowther
Journal:  Cochrane Database Syst Rev       Date:  2022-08-31

3.  Fetal malposition in labour and health outcomes for women and their newborn infants: A retrospective cohort study.

Authors:  Jennifer Barrowclough; Bridget Kool; Caroline Crowther
Journal:  PLoS One       Date:  2022-10-19       Impact factor: 3.752

4.  Randomised controlled trial of effect of hands and knees posturing on incidence of occiput posterior position at birth.

Authors:  Azar Kariminia; Marie E Chamberlain; John Keogh; Agnes Shea
Journal:  BMJ       Date:  2004-01-26

5.  Sonographic evaluation in the second stage of labor to improve the assessment of labor progress and its outcome.

Authors:  Lami Yeo; Roberto Romero
Journal:  Ultrasound Obstet Gynecol       Date:  2009-03       Impact factor: 7.299

6.  Delivery Mode After Manual Rotation of Occiput Posterior Fetal Positions: A Randomized Controlled Trial.

Authors:  Caroline Verhaeghe; Romain Corroenne; Andrew Spiers; Philippe Descamps; Géraldine Gascoin; Pierre-Emmanuel Bouet; Elsa Parot-Schinkel; Guillaume Legendre
Journal:  Obstet Gynecol       Date:  2021-06-01       Impact factor: 7.661

7.  Persistent Occiput Posterior position - OUTcomes following manual rotation (POP-OUT): study protocol for a randomised controlled trial.

Authors:  Hala Phipps; Jon A Hyett; Sabrina Kuah; John Pardey; Joanne Ludlow; Andrew Bisits; Felicity Park; David Kowalski; Bradley de Vries
Journal:  Trials       Date:  2015-03-15       Impact factor: 2.279

8.  Instrumental rotation for persistent fetal occiput posterior position: a way to decrease maternal and neonatal injury?

Authors:  Fabien Vidal; Caroline Simon; Christelle Cristini; Catherine Arnaud; Olivier Parant
Journal:  PLoS One       Date:  2013-10-18       Impact factor: 3.240

9.  Maternal positioning to correct occipito-posterior fetal position in labour: a randomised controlled trial.

Authors:  Marie-Julia Guittier; Véronique Othenin-Girard; Olivier Irion; Michel Boulvain
Journal:  BMC Pregnancy Childbirth       Date:  2014-02-24       Impact factor: 3.007

10.  Effect on birth outcomes of a formalised approach to care in hospital labour assessment units: international, randomised controlled trial.

Authors:  Ellen D Hodnett; Robyn Stremler; Andrew R Willan; Julie A Weston; Nancy K Lowe; Kathleen R Simpson; William D Fraser; Amiram Gafni
Journal:  BMJ       Date:  2008-08-28
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.