Literature DB >> 9570105

AOX-emissions from hospitals into municipal waste water.

K Kümmerer1, T Erbe, S Gartiser, L Brinker.   

Abstract

Adsorbable organically bound halogens (AOX) are mostly persistent in the environment, and accumulate in the food web. Some of them are toxic to humans and other organisms. AOX were measured in the effluents from six German hospitals of different size and departments like internal medicine and ear-nose and throat (ENT) as well as from laundry, kitchen and laboratory. The concentrations in the day time mixed samples of the total effluent were 0.13 mg l(-1)-0.94 mg l-1 (phi = 0.43 mg l-1). For the separately investigated departments the lowest concentrations were found in the effluent from laundry and kitchen (0.015 mg l-1), and the highest ones in the effluents from the medical departments (0.12-1.71 mg l-1, phi 0.95 mg l-1 during the week and 0.06-0.10 mg l-1 at the week-end) and the laboratories (0.05-14.2 mg l-1, phi 2.73 mg l-1). The AOX concentration in night time mixed samples were 0.07-0.41 mg l-1 (phi = 0.41 mg l-1) for the total effluents and 0.25-2.64 mg l-1 (phi = 1.11 mg l-1) for medical departments. Concentrations expected by computing the input of AOX attributable to pharmaceuticals were between 11% and 16% for two hospitals and 7.7% for an ENT department. One additional important source of AOX in hospital effluents may be x-ray contrast media containing a iodine carbon bond.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9570105     DOI: 10.1016/s0045-6535(97)10200-4

Source DB:  PubMed          Journal:  Chemosphere        ISSN: 0045-6535            Impact factor:   7.086


  5 in total

1.  Two-year survey of specific hospital wastewater treatment and its impact on pharmaceutical discharges.

Authors:  Laure Wiest; Teofana Chonova; Alexandre Bergé; Robert Baudot; Frédérique Bessueille-Barbier; Linda Ayouni-Derouiche; Emmanuelle Vulliet
Journal:  Environ Sci Pollut Res Int       Date:  2017-07-17       Impact factor: 4.223

2.  Treatment of hospital laundry wastewater by UV/H2O2 process.

Authors:  Jaqueline Pirão Zotesso; Eneida Sala Cossich; Vanderly Janeiro; Célia Regina Granhen Tavares
Journal:  Environ Sci Pollut Res Int       Date:  2016-05-28       Impact factor: 4.223

Review 3.  What have we learned from worldwide experiences on the management and treatment of hospital effluent? - an overview and a discussion on perspectives.

Authors:  P Verlicchi; M Al Aukidy; E Zambello
Journal:  Sci Total Environ       Date:  2015-02-16       Impact factor: 7.963

Review 4.  Current Trends in the Application of Nanomaterials for the Removal of Pollutants from Industrial Wastewater Treatment-A Review.

Authors:  Geetha Palani; A Arputhalatha; Karthik Kannan; Sivarama Krishna Lakkaboyana; Marlia M Hanafiah; Vinay Kumar; Ravi Kumar Marella
Journal:  Molecules       Date:  2021-05-10       Impact factor: 4.411

Review 5.  SARS-CoV-2 in hospital wastewater during outbreak of COVID-19: A review on detection, survival and disinfection technologies.

Authors:  Mounia Achak; Soufiane Alaoui Bakri; Younes Chhiti; Fatima Ezzahrae M'hamdi Alaoui; Noureddine Barka; Wafaa Boumya
Journal:  Sci Total Environ       Date:  2020-10-24       Impact factor: 7.963

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.