Mechanical behavior of human morselized cancellous bone in triaxial compression testing.

M D Brodt1, C C Swan, T D Brown.   

Abstract

Despite its widespread use as graft material in orthopaedic surgical procedures, morselized cancellous bone has not yet been well characterized from the standpoint of its mechanical properties. To accommodate the noncohesive nature of this loose particulate form of bone, a triaxial compression test apparatus commonly used in engineering soil mechanics was adapted for the testing of fresh-frozen human morselized cancellous bone specimens. Triaxial compression tests were run to 30% axial strain at five different levels of confining pressure ranging from 0.276 to 0.552 MPa. The measured axial stress versus axial strain behavior was bimodal, characterized initially by relatively stiff linear behavior, then by a rapid transition to a much more compliant (but, again, approximately linear) domain until test cessation. The apparent axial moduli of both response regions were found to be nearly linear functions of the transverse confining pressure. As typically prepared surgically, the distribution of particle size was found to have approximately 80% of the bone graft, by weight, encompassed in particles 0.42-3.2 mm in size. Triaxial tests of samples segregated by size showed that particle size had no appreciable effect on apparent material properties. The nominal Young's modulus and Poisson's ratio of morselized cancellous bone were 100 MPa and 0.2, respectively.

Entities:  

Mesh:

Year:  1998        PMID: 9565072     DOI: 10.1002/jor.1100160108

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  8 in total

1.  Determination of mechanical properties of impacted human morsellized cancellous allografts for revision joint arthroplasty.

Authors:  Y Tanabe; T Wakui; A Kobayashi; H Ohashi; Y Kadoya; Y Yamano
Journal:  J Mater Sci Mater Med       Date:  1999-12       Impact factor: 3.896

2.  The combined effect of parathyroid hormone and bone graft on implant fixation.

Authors:  H Daugaard; B Elmengaard; T T Andreassen; J Baas; J E Bechtold; K Soballe
Journal:  J Bone Joint Surg Br       Date:  2011-01

3.  [Use of the injectable bone cement Norian SRS for tibial plateau fractures. Results of a prospective 30-month follow-up study].

Authors:  A Jubel; J Andermahr; J Mairhofer; A Prokop; U Hahn; K E Rehm
Journal:  Orthopade       Date:  2004-08       Impact factor: 1.087

4.  Acetabular reinforcement ring with additional hook improves stability in three-dimensional finite element analyses of dysplastic hip arthroplasty.

Authors:  Koji Totoribe; Etsuo Chosa; Go Yamako; Xin Zhao; Koki Ouchi; Hiroaki Hamada; Gang Deng
Journal:  J Orthop Surg Res       Date:  2018-12-07       Impact factor: 2.359

5.  Comparative finite element analysis of mandibular posterior single zirconia and titanium implants: a 3-dimensional finite element analysis.

Authors:  Sung-Min Choi; Hyunsuk Choi; Du-Hyeong Lee; Min-Ho Hong
Journal:  J Adv Prosthodont       Date:  2021-12-22       Impact factor: 1.904

6.  Autologous versus synthetic bone grafts for the surgical management of tibial plateau fractures: a systematic review and meta-analysis of randomized controlled trials.

Authors:  George M Cooper; Matthew J Kennedy; Bilal Jamal; David W Shields
Journal:  Bone Jt Open       Date:  2022-03

7.  Finite element analysis of the tibial bone graft in cementless total knee arthroplasty.

Authors:  Koji Totoribe; Etsuo Chosa; Go Yamako; Hiroaki Hamada; Koki Ouchi; Shutaro Yamashita; Gang Deng
Journal:  J Orthop Surg Res       Date:  2018-05-16       Impact factor: 2.359

8.  Finite element analysis of a one-piece zirconia implant in anterior single tooth implant applications.

Authors:  Georgi Talmazov; Nathan Veilleux; Aous Abdulmajeed; Sompop Bencharit
Journal:  PLoS One       Date:  2020-02-24       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.