Literature DB >> 9564914

Easy harvesting of radial artery with ultrasonically activated scalpel.

H Psacioğlu1, Y Atay, B Cetindağ, O Saribülbül, S Buket, A Hamulu.   

Abstract

BACKGROUND: The radial artery was proposed and then abandoned as a coronary artery bypass graft in the 1970s. Development of new pharmacologic antispasmodic agents and minimally traumatic harvesting techniques has led to a revival of the use of the radial artery in coronary artery bypass surgery. Usually the main reasons for the spasm are thermal injury caused by electrocautery and traumatic harvesting technique.
METHODS: In our technique an ultrasonically activated scalpel (Harmonic Scalpel; Ultracision Inc, Smithfield, RI) was used for radial artery harvesting without using hemostatic clips for vessel side branches. The patients in the study were divided into two groups of 10 patients each. In the first group radial arteries were harvested with this technique, and in the second group with hemostatic clips, scissors, and minimal electrocautery. Harvesting time, frequency of spasm, and use of hemostatic clips were compared between the two groups.
RESULTS: The Harmonic Scalpel decreased the harvesting time, frequency of spasm, and excessive use of hemostatic clips.
CONCLUSIONS: Good coagulation capacity with markedly decreased use of hemostatic clips and minimized thermal injury offers the surgeon the ability to perform less traumatic, spasm free, and rapid radial artery harvesting.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9564914     DOI: 10.1016/s0003-4975(98)00059-9

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  4 in total

1.  Ultrasonically activated shears in thyroidectomies: a randomized trial.

Authors:  P E Voutilainen; C H Haglund
Journal:  Ann Surg       Date:  2000-03       Impact factor: 12.969

2.  Ultrasonic coagulator for video-assisted internal mammary artery harvest.

Authors:  T Ohtsuka; S Takamoto; M Endoh; Y Kotsuka; T Oka
Journal:  Surg Endosc       Date:  2000-01       Impact factor: 4.584

3.  Optical coherence tomography imaging as a quality assurance tool for evaluating endoscopic harvest of the radial artery.

Authors:  Nicholas S Burris; Emile N Brown; Michael Grant; Zachary N Kon; Marc Gibber; Junyen Gu; Kimberly Schwartz; Seeta Kallam; Ashish Joshi; Richard Vitali; Robert S Poston
Journal:  Ann Thorac Surg       Date:  2008-04       Impact factor: 4.330

4.  Comparison of Sharp Dissection, Electrocautery, and Ultrasonic Activated Scalpel with Regard to Endothelial Damage, Preparation Time, and Postoperative Bleeding During Radial Artery Harvesting.

Authors:  Dinçer Uysal; Şenol Gülmen; Hayrettin Özkan; Ulaş Sağlam; Mustafa Etli; Sema Bircan; Recep Sütçü; Turhan Yavuz; Hakan Öntaş; Fatih Aksoy
Journal:  Braz J Cardiovasc Surg       Date:  2019-12-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.