Influence of different pilot hole sizes on torque measurements and pullout analysis of osteosynthesis screws.

W Heidemann1, K L Gerlach, K H Gröbel, H G Köllner.   

Abstract

When screws are inserted in thick cortical bone, a small pilot hole size, corresponding to the core diameter of the screw, can result in high torsional stress, leading to screw fracture. The aim of this study was to enlarge the drill size up to a critical pilot hole size (CPHS) which, if exceeded, means a rapid decrease in the screw holding power. 1.5 and 2 mm titanium screws were inserted in discs of polyvinylchloride (PVC), wood and porcine mandibular bone with thicknesses differing between 2 to 4 mm, using an increasing pilot hole size between 66% and 95% of the screw external diameter. Torque measurements and pullout tests were performed and the CPHS was calculated. In torque measurements, the CPHS of microscrews ranged between 83% and 85% of the screw external diameter (SED). The CPHS of miniscrews lay between 80% and 90% of SED. In pullout analysis, the CPHS of microscrews ranged between 83% and 89% of SED; the CPHS of miniscrews lay between 79% and 91% of SED. The mean of the CPHS was calculated to be approximately 85% of the SED. Up to this critical point, the pilot hole size may be increased without affecting the holding power of the screws.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9563595     DOI: 10.1016/s1010-5182(98)80035-8

Source DB:  PubMed          Journal:  J Craniomaxillofac Surg        ISSN: 1010-5182            Impact factor:   2.078


  9 in total

1.  How pilot-hole size affects bone-screw pullout strength in human cadaveric cancellous bone.

Authors:  Mark Steeves; Craig Stone; John Mogaard; Stephanie Byrne
Journal:  Can J Surg       Date:  2005-06       Impact factor: 2.089

2.  Biomechanical properties of orthodontic miniscrews. An in-vitro study.

Authors:  Britta Florvaag; Peter Kneuertz; Frank Lazar; Jürgen Koebke; Joachim E Zöller; Bert Braumann; Robert A Mischkowski
Journal:  J Orofac Orthop       Date:  2010-02-05       Impact factor: 1.938

3.  New implant designs for fracture fixation in osteoporotic bone.

Authors:  J Goldhahn; J Seebeck; R Frei; B Frenz; I Antoniadis; E Schneider
Journal:  Osteoporos Int       Date:  2004-11-05       Impact factor: 4.507

4.  Analysis of biological and structural factors implicated in the clinical success of orthodontic miniscrews at posterior maxillary interradicular sites.

Authors:  M Palone; A Darsiè; G B Maino; G Siciliani; G A Spedicato; L Lombardo
Journal:  Clin Oral Investig       Date:  2021-11-27       Impact factor: 3.573

5.  Effects of predrilling depth and implant shape on the mechanical properties of orthodontic mini-implants during the insertion procedure.

Authors:  Keun-Chul Cho; Seung-Hak Baek
Journal:  Angle Orthod       Date:  2011-11-03       Impact factor: 2.079

6.  Comparative evaluation of insertion torque and mechanical stability for self-tapping and self-drilling orthodontic miniscrews - an in vitro study.

Authors:  Michele Tepedino; Francesco Masedu; Claudio Chimenti
Journal:  Head Face Med       Date:  2017-05-30       Impact factor: 2.151

7.  Drilling Capability of Orthodontic Miniscrews: In Vitro Study.

Authors:  Alessandra Marchi; Matteo Camporesi; Maurizio Festa; Luis Salvatierra; Sara Izadi; Giampietro Farronato
Journal:  Dent J (Basel)       Date:  2020-12-21

8.  Comparison and prediction of pullout strength of conical and cylindrical pedicle screws within synthetic bone.

Authors:  Wen-Chi Tsai; Po-Quang Chen; Tung-Wu Lu; Shing-Sheng Wu; Kao-Shang Shih; Shang-Chih Lin
Journal:  BMC Musculoskelet Disord       Date:  2009-04-30       Impact factor: 2.362

9.  Effects of polymethylmethacrylate on the stability of screw fixation in mandibular angle fractures: A study on sheep mandibles.

Authors:  Abdulkadir Burak Cankaya; Metin Berk Kasapoglu; Mehmet Ali Erdem; Cetin Kasapoglu
Journal:  Int J Med Sci       Date:  2018-09-11       Impact factor: 3.738

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.