Literature DB >> 9562074

Enhancement of phase-contrast MR angiography with superparamagnetic iron oxide.

A Tanimoto1, Y Yuasa, K Hiramatsu.   

Abstract

The effect of superparamagnetic iron oxide particles (AMI-227) was assessed in three-dimensional (3D) phase-contrast (PC) MR angiography (MRA), with various scanning parameters for rats at 1.5 T. The blood T1 and T2 before and after 20 micromol Fe/kg of AMI-227 injection were measured sequentially at .47 T. The visualization of abdominal aorta, renal artery, inferior vena cava, and portal vein was respectively evaluated before and after AMI-227 injection qualitatively by the four confidence levels and quantitatively by analysis of signal-to-noise ratio (SNR) of vessels. The blood T1 and T2 were sufficiently shortened for at least 1 hour after AMI-227 injection. The visualization of each vessel was improved by AMI-227 at various velocity encoding (VENC) value, suggesting the extended application of PC-MRA in various conditions. The optimal flip angle was increased from 20 degrees to 30 degrees in higher VENC after AMI-227 injection, resulting in higher signal from blood flow. Quantitative analyses showed that the optimal flip angle to achieve the maximum SNR seemed to be 20 degrees in unenhanced images, but the optimal flip angle of the high speed flow was increased by contrast enhancement. The postcontrast PC-MRA provides the increased sensitivity of slow flow components, even with a high VENC gradient. AMI-227 can significantly improve SNR to blood vessels during 3D-PC-MRA with various scanning parameters.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9562074     DOI: 10.1002/jmri.1880080227

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  2 in total

1.  Standardized MR protocol for the evaluation of MRA sequences and/or contrast agents effects in high-degree arterial stenosis analysis.

Authors:  Bruno Marchand; Philippe C Douek; Philippe Robert; Claire Corot; Jean Pierre Roux; Patrice Adeleine; Marcela Hernandez-Hoyos; Yannick Cremillieux; Maciej Orkisz; Emmanuelle Canet
Journal:  MAGMA       Date:  2002-06       Impact factor: 2.533

2.  Effect of Flip Angle on the Correlation Between Signal Intensity and Different Concentrations of Iron Oxide Nanoparticles Using T1-Weighted Turbo-FLASH Inversion Recovery Sequence.

Authors:  Nahideh Gharehaghaji; Mahmood Nazarpoor; Hodaiseh Saharkhiz
Journal:  Iran J Radiol       Date:  2015-04-22       Impact factor: 0.212

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.