Literature DB >> 9554641

Effect of high-frequency oral airway and chest wall oscillation and conventional chest physical therapy on expectoration in patients with stable cystic fibrosis.

T A Scherer1, J Barandun, E Martinez, A Wanner, E M Rubin.   

Abstract

STUDY
OBJECTIVE: To compare the effect of high-frequency oral airway oscillation, high-frequency chest wall oscillation, and conventional chest physical therapy (CPT) on weight of expectorated sputum, pulmonary function, and oxygen saturation in outpatients with stable cystic fibrosis (CF).
DESIGN: Prospective randomized trial.
SETTING: Pediatric pulmonary division of a tertiary care center. PATIENTS: Fourteen outpatients with stable CF recruited from the CF center.
INTERVENTIONS: Two modes of oral airway oscillation (1: frequency 8 Hz; inspiratory to expiratory [I:E] ratio 9:1; 2: frequency 14 Hz; I:E ratio 8:1), two modes of chest wall oscillation (1: frequency 3 Hz; I:E ratio 4:1; 2: frequency 16 Hz; I:E ratio 1:1, alternating with frequency 1.5 Hz, I:E ratio 6:1), and CPT (clapping, vibration, postural drainage, and encouraged coughing) were applied during the first 20 min of 4 consecutive hours. MEASUREMENTS AND
RESULTS: Sputum was collected on an hourly basis for a total of 6 consecutive hours. During the first and the last hour, patients collected sputum without having any treatment and underwent pulmonary function tests (PFTs). Oxygen saturation was measured at 30-min intervals during hours 1 to 6. For the first 20 min of the second to the fifth hour, patients received one of the treatments. To assess the effect of the intervention, the weight of expectorated sputum during hours 2 to 6 was averaged and expressed as percentage of the weight expectorated during the first hour (baseline). For the five treatment modalities, mean sputum dry and wet weights ranged between 122% and 185% of baseline. There was no statistically significant difference among the treatment modalities. As measured by sputum wet weight, all oscillatory devices tended to be less effective than CPT (p=0.15). As measured by dry weight, oral airway oscillation at 8 Hz with an I:E ratio of 9:1 and CPT tended to be more effective than the other treatment modalities (p=0.57). None of the treatment modalities had an effect on PFTs and oxygen saturation and all were well tolerated.
CONCLUSION: In outpatients with stable CF, high-frequency oscillation applied via the airway opening or via the chest wall and CPT have comparable augmenting effects on expectorated sputum weight without changing PFTs or oxygen saturation. In contrast to CPT, high-frequency oral airway and chest wall oscillations are self-administered, thereby containing health-care expenses.

Entities:  

Mesh:

Year:  1998        PMID: 9554641     DOI: 10.1378/chest.113.4.1019

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  13 in total

Review 1.  Physiotherapy in cystic fibrosis.

Authors:  S A Prasad; E L Tannenbaum; C Mikelsons
Journal:  J R Soc Med       Date:  2000       Impact factor: 5.344

2.  Oscillating devices for airway clearance in people with cystic fibrosis.

Authors:  Lisa Morrison; Stephanie Milroy
Journal:  Cochrane Database Syst Rev       Date:  2020-04-30

Review 3.  Structure and function of the mucus clearance system of the lung.

Authors:  Brenda M Button; Brian Button
Journal:  Cold Spring Harb Perspect Med       Date:  2013-08-01       Impact factor: 6.915

4.  Intrapulmonary percussive ventilation in tracheostomized patients: a randomized controlled trial.

Authors:  Enrico M Clini; Francesca Degli Antoni; Michele Vitacca; Ernesto Crisafulli; Mara Paneroni; Sheila Chezzi-Silva; Maurizio Moretti; Ludovico Trianni; Leonardo M Fabbri
Journal:  Intensive Care Med       Date:  2006-10-24       Impact factor: 17.440

Review 5.  Oscillating devices for airway clearance in people with cystic fibrosis.

Authors:  Lisa Morrison; Stephanie Innes
Journal:  Cochrane Database Syst Rev       Date:  2017-05-04

Review 6.  Conventional chest physiotherapy compared to other airway clearance techniques for cystic fibrosis.

Authors:  E Main; A Prasad; C Schans
Journal:  Cochrane Database Syst Rev       Date:  2005-01-25

7.  High-frequency percussive ventilation for airway clearance in cystic fibrosis: a brief report.

Authors:  Dayton Dmello; Ravi P Nayak; George M Matuschak
Journal:  Lung       Date:  2010-07-03       Impact factor: 2.584

8.  Airway clearance devices for cystic fibrosis: an evidence-based analysis.

Authors: 
Journal:  Ont Health Technol Assess Ser       Date:  2009-11-01

9.  Chest high-frequency oscillatory treatment for severe atelectasis in a patient with toxic epidermal necrolysis.

Authors:  Shiara Ortiz-Pujols; Laura A Boschini; Cristine Klatt-Cromwell; Kathy A Short; James Hwang; Bruce A Cairns; Samuel W Jones
Journal:  J Burn Care Res       Date:  2013 Mar-Apr       Impact factor: 1.845

10.  Current devices of respiratory physiotherapy.

Authors:  A Hristara-Papadopoulou; J Tsanakas; G Diomou; O Papadopoulou
Journal:  Hippokratia       Date:  2008       Impact factor: 0.471

View more