Literature DB >> 9554482

Determination of gene dosage at the PMP22 and androgen receptor loci by quantitative PCR.

R A Poropat1, G A Nicholson.   

Abstract

UNLABELLED: Although many genetic diseases are caused by the presence of point mutations in respective genes, an increasing number of diseases are known to be caused by gene copy number changes. We report the development of a rapid and reliable PCR-based method for quantitation of gene copy number with sufficient sensitivity to detect single copy changes without the use of radioactive or fluorescent labeling. The sensitivity of this technique has been demonstrated by the detection of the DNA duplication or deletion occurring in two inherited peripheral neuropathies, Charcot-Marie-Tooth type 1A (CMT1A) and hereditary neuropathy with liability to pressure palsies (HNPP), that are caused by a reciprocal duplication or deletion event on chromosome 17p11.2-12. This method relies on the comparison of the amount of PCR product generated from a potentially duplicated or deleted target sequence with the amount of product generated from a disomic reference gene. The value of this ratio (target PCR product:reference PCR product) indicates whether the target sequence is duplicated, deleted, or unchanged. Using primers from within a duplicated or deleted region (PMP22 gene and EW401) and from within a reference region (NF1 gene), we tested 50 CMT1A, 30 HNPP, and 50 unaffected individuals for the presence of a DNA duplication or deletion. TARGET: reference ratios of 1.58, 1.02, and 0.56 were detected for the CMT1A, unaffected, and HNPP groups, respectively. Thus, differentiation of the three groups of individuals was on the basis of gene copy number. This technique was successfully used to detect the difference in the X chromosome copy number between males and females (target:reference ratios of 1.1 and 2.3, respectively). This approach to the detection of DNA duplications and deletions is sensitive, accurate, and has potential applications in the quantitation of changes in gene copy number associated with diseases characterized by such chromosomal alterations.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9554482

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  3 in total

Review 1.  Chromosomal abnormality, laboratory techniques, tools and databases in molecular Cytogenetics.

Authors:  Abbasali Emamjomeh; Behzad Hajieghrari; Somayeh Montazerinezhad
Journal:  Mol Biol Rep       Date:  2020-10-26       Impact factor: 2.316

2.  Effectiveness of real-time quantitative PCR compare to repeat PCR for the diagnosis of Charcot-Marie-Tooth Type 1A and hereditary neuropathy with liability to pressure palsies.

Authors:  Jong Rak Choi; Woon Hyoung Lee; Il Nam Sunwoo; Eun Kyung Lee; Chang Hoon Lee; Jong Baeck Lim
Journal:  Yonsei Med J       Date:  2005-06-30       Impact factor: 2.759

3.  A rapid and reliable detection system for the analysis of PMP22 gene dosage by MP/DHPLC assay.

Authors:  Chia-Yun Lin; Yi-Ning Su; Chien-Nan Lee; Chia-Cheng Hung; Wen-Fang Cheng; Win-Li Lin; Chi-An Chen; Sung-Tsang Hsieh
Journal:  J Hum Genet       Date:  2006-02-04       Impact factor: 3.172

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.