Literature DB >> 9553881

Laser welding of a cobalt-chromium removable partial denture alloy.

D P NaBadalung1, J I Nicholls.   

Abstract

STATEMENT OF PROBLEM: The electric alloy brazed joints of removable partial denture alloys have failed frequently after routine usage.
PURPOSE: A technique providing higher joint strengths was investigated. This investigation compared the tensile strengths of electric-brazed and laser-welded joints for a cobalt-chromium removable partial denture alloy.
MATERIAL AND METHODS: Twenty-four cobalt-chromium standard tensile testing rods were prepared and divided into three groups of eight. All specimens in the control group (group 1) were left in the as-cast condition. Groups 2 and 3 were the test specimens, which were sectioned at the center of the rod. Eight specimens were joined by using electric brazing, and the remaining specimens were joined by using laser welding. After joining, each joint was ground to a uniform diameter, then tested to tensile failure on an Instron universal testing machine. Failure loads were recorded and fracture stress calculated. Statistical analysis was applied.
RESULTS: The student-Newman-Keuls test showed a highly significant difference between the joint strengths of the as-cast control specimens, the electric-brazed and laser-welded joints.
CONCLUSIONS: The tensile strengths of the as-cast joints were higher than those for the laser-welded joints, and both were higher than the electric-brazed joint strengths.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9553881     DOI: 10.1016/s0022-3913(98)70239-2

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  3 in total

1.  Effects of conventional welding and laser welding on the tensile strength, ultimate tensile strength and surface characteristics of two cobalt-chromium alloys: a comparative study.

Authors:  Seenivasan Madhan Kumar; Jayesh Raghavendra Sethumadhava; Vaidyanathan Anand Kumar; Grover Manita
Journal:  J Indian Prosthodont Soc       Date:  2012-04-18

2.  Effect of Nd:YAG laser parameters on the penetration depth of a representative Ni-Cr dental casting alloy.

Authors:  Youssef S Al Jabbari; Theodoros Koutsoukis; Xanthoula Barmpagadaki; Ehab A El-Danaf; Raymond A Fournelle; Spiros Zinelis
Journal:  Lasers Med Sci       Date:  2013-12-11       Impact factor: 3.161

3.  Mechanical and interfacial characterization of laser welded Co-Cr alloy with different joint configurations.

Authors:  John Kokolis; Makdad Chakmakchi; Antonios Theocharopoulos; Anthony Prombonas; Spiros Zinelis
Journal:  J Adv Prosthodont       Date:  2015-02-17       Impact factor: 1.904

  3 in total