Working parameters of a sonic scaler influencing root substance removal in vitro.

T F Flemmig1, G J Petersilka, A Mehl, S Rüdiger, R Hickel, B Klaiber.   

Abstract

This study assessed defect depth and volume resulting from root instrumentation using a KaVo Sonic-flex Lux 2000 L sonic scaler with a slim scaling tip (Perio-Tip no. 8) in vitro. Combinations of the following working parameters were analyzed: lateral forces of 0.5 N, 1 N, and 2 N; tip angulations of 0 degree, 45 degrees, and 90 degrees; and instrumentation time of 10 s, 20 s, 40 s, and 80 s. Defects were quantified using a three-dimensional optical laser scanner. Instrumentation time had an almost linear impact on defect depth and volume. Although lateral force (beta-weight 0.55 +/- 0.062) had a greater influence on defect volume than tip angulation (beta-weight 0.29 +/- 0.062), their effects on defect depth were similar (beta-weight 0.43 +/- 0.052 and 0.50 +/- 0.052, respectively). The combination of force and angulation showed synergistic effects resulting in a wide range of defect depths (21.9 +/- 0.96 microns to 174 +/- 28.8 microns, at 40 s) and volumes (0.056 +/- 0.019 mm3 to 0.68 +/- 0.10 mm3 at 40 s). Severe root damage (> 50 microns/40 s) did not occur at any combination of 0.5 N lateral force and/or 0 degree tip angulation. By adjusting lateral force and tip angulation, the efficacy of the assessed sonic scaler may be adapted to various clinical needs.

Entities:  

Mesh:

Year:  1997        PMID: 9552818     DOI: 10.1007/s007840050011

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  5 in total

1.  Mapping cavitation activity around dental ultrasonic tips.

Authors:  A Damien Walmsley; Simon C Lea; Bernhard Felver; David C King; Gareth J Price
Journal:  Clin Oral Investig       Date:  2012-08-15       Impact factor: 3.573

2.  Influence of Different Proportions of External Irrigation During the Er,Cr:YSGG Laser Irradiation on Wear and Roughness of Root Surface.

Authors:  Guilherme José Pimentel Lopes de Oliveira; Felipe Eduardo Pinotti; Heglécia da Luz Carvalho; Cássio Rocha Scardueli; Rosemary Adriana Chiérici Marcantonio
Journal:  J Lasers Med Sci       Date:  2016-01-07

3.  Subgingival instrumentation to remove simulated plaque in vitro: influence of operators' experience and type of instrument.

Authors:  Christian Graetz; Falk Schwendicke; Anna Plaumann; Sebastian Rauschenbach; Claudia Springer; Maren Kahl; Sonja Sälzer; Christof E Dörfer
Journal:  Clin Oral Investig       Date:  2014-09-19       Impact factor: 3.573

4.  Efficacy versus health risks: An in vitro evaluation of power-driven scalers.

Authors:  Christian Graetz; Anna Plaumann; Jule Bielfeldt; Anica Tillner; Sonja Sälzer; Christof Edmund Dörfer
Journal:  J Indian Soc Periodontol       Date:  2015 Jan-Feb

5.  Evaluation of a systematic digitized training program on the effectivity of subgingival instrumentation with curettes and sonic scalers in vitro.

Authors:  Christian Graetz; Paula Fecke; Miriam Seidel; Anne Sophie Engel; Susanne Schorr; Johanna Sentker; Christof E Dörfer; Sonja Sälzer
Journal:  Clin Oral Investig       Date:  2020-05-30       Impact factor: 3.573

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.