Literature DB >> 9550573

Mechanisms of dopamine and dobutamine interference in biochemical tests that use peroxide and peroxidase to generate chromophore.

B S Karon1, T M Daly, M G Scott.   

Abstract

Dopamine and dobutamine have recently been shown to produce a negative interference in several biochemical tests that use peroxide and peroxidase to generate a chromophore. To define the chemical mechanism of this interference, we examined the effects of dopamine and dobutamine in various peroxidase-based biochemical tests. Dopamine interfered stoichiometrically with peroxidase-based tests that use 4-aminophenazone to form chromophore but interfered little in those that use other compounds to generate chromophore. Dopamine reacts with 4-aminophenazone in the presence of peroxide and peroxidase to form a novel quinone-imine dye, with a smaller absorptivity than the chromophore formed in the absence of dopamine. The smaller absorptivity of this novel chromophore results in negative interference by reducing the total absorbance at the wavelength used to measure analyte. In contrast, dobutamine interfered stoichiometrically with all peroxidase-based tests studied, regardless of whether 4-aminophenazone was used to form the chromophore. Dobutamine was rapidly oxidized by peroxide in the presence of peroxidase, thus depleting the peroxide necessary to generate chromophore. Dopamine and dobutamine demonstrate two distinct general mechanisms of interference in peroxidase-based biochemical tests.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9550573

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  4 in total

1.  Measurement of serum creatinine--current status and future goals.

Authors:  Michael Peake; Malcolm Whiting
Journal:  Clin Biochem Rev       Date:  2006-11

2.  Falsely Elevated Creatinine on Enzymatic Assay in a Patient Receiving Subcutaneous IgG Therapy.

Authors:  Ashley R Santilli; Mark L Wieland
Journal:  J Gen Intern Med       Date:  2021-02-05       Impact factor: 5.128

3.  Combined strategy of knowledge-based rule selection and historical data percentile-based range determination to improve an autoverification system for clinical chemistry test results.

Authors:  Jing Zhu; Hao Wang; Beili Wang; Xiaoke Hao; Wei Cui; Yong Duan; Yi Zhang; Liang Ming; Yingchun Zhou; Haitao Ding; Hongling Ou; Weiwei Lin; Liu Lu; Yuanjiang Shang; Yong Yang; Xianming Liang; Jiangtao Ma; Wenhua Sun; Te Chen; Guang Han; Meng Han; Weiting Yu; Baishen Pan; Wei Guo
Journal:  J Clin Lab Anal       Date:  2022-01-10       Impact factor: 2.352

4.  Analytical performance evaluation of different test systems on serum creatinine assay.

Authors:  Lina He; Jinqi Yu; Guang Han; Di Huang; Liqiao Han; Qiaoxuan Zhang; Yunxiu Wang; Zemin Wan; Xian-Zhang Huang; Yujuan Xiong; Xiaobin Wu
Journal:  J Clin Lab Anal       Date:  2021-12-26       Impact factor: 2.352

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.