Quantification of sonographic echogenicity with grey-level histogram width: a clinical tissue characterization.

K Maeda1, M Utsu, P E Kihaile.   

Abstract

Grey-level histogram width (GLHW) values obtained by common sonographic devices were large in echogenic image and small in less echoic parts. The Aloka UIP-100 computer system, SSD-680, and Toshiba SSA-270A sonographs showed GLHW values not significantly different when tested with RMI-412 phantom with the device contrast set at the lowest level. No influence on the GLHW value was observed by the changes of device gain, STC or image depth in the range of clinical practice. Device contrast control influenced the value. Although two sonographs showed significant differences from UIP-100, they were easily corrected by a small factor. Normal ranges of GLHW values of the placenta were obtained every 2 weeks, from 20 to 41 weeks, in 222 normal pregnancies measured by old scanners. GLHW values of normal pregnancies measured by the new Aloka and Toshiba machines were distributed within the normal ranges, and those of Grannum Grade III abnormally echogenic placenta were greater than the upper normal range. GLHW is a reproducible value among commercial ultrasonic devices, and the value is useful in clinical practice. Manual and automated GLHW values were identical.

Entities:  

Mesh:

Year:  1998        PMID: 9550181     DOI: 10.1016/s0301-5629(97)00266-4

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  6 in total

1.  Efficiency of quantitative echogenicity for investigating supraspinatus tendinopathy by the gray-level histogram of two ultrasound devices.

Authors:  Jiun-Cheng Hsu; Po-Han Chen; Kuo-Chin Huang; Yao-Hung Tsai; Wei-Hsiu Hsu
Journal:  J Med Ultrason (2001)       Date:  2017-02-14       Impact factor: 1.314

2.  Quantification of sonographic echogenicity by the gray-level histogram in patients with supraspinatus tendinopathy.

Authors:  Yao-Hung Tsai; Kuo-Chin Huang; Shih-Hsun Shen; Tien-Yu Yang; Tsung-Jen Huang; Robert Wen-Wei Hsu
Journal:  J Med Ultrason (2001)       Date:  2013-12-27       Impact factor: 1.314

3.  Tissue characterization of uterine myometrium using the ultrasound gray-level histogram width.

Authors:  Takashi Ito; Koichi Ishihara; Imari Deura; Chieko Katagiri; Kazuo Maeda
Journal:  J Med Ultrason (2001)       Date:  2007-12-14       Impact factor: 1.314

4.  Histogram analysis of hepatobiliary phase MR imaging as a quantitative value for liver cirrhosis: preliminary observations.

Authors:  Jin-Young Choi; Honsoul Kim; Mark Sun; Claude B Sirlin
Journal:  Yonsei Med J       Date:  2014-04-01       Impact factor: 2.759

5.  Feasibility of histogram analysis of susceptibility-weighted MRI for staging of liver fibrosis.

Authors:  Zhao Xia Yang; He Yue Liang; Xin Xing Hu; Ya Qin Huang; Ying Ding; Shan Yang; Meng Su Zeng; Sheng Xiang Rao
Journal:  Diagn Interv Radiol       Date:  2016 Jul-Aug       Impact factor: 2.630

6.  The Role of Real-Time Tissue Elastography and Gray-Scale Ultrasound Histogram Analysis in the Diagnosis of Patients With Sjögren's Syndrome.

Authors:  İlhan Sezer; İclal Erdem Toslak; Buket Yağci; Funda Erbasan; Ayşe Ayan; Uğur Karasu
Journal:  Arch Rheumatol       Date:  2019-03-28       Impact factor: 1.472

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.