Study of creep behavior of ultra-high-molecular-weight polyethylene systems.

M Deng1, R A Latour, A A Ogale, S W Shalaby.   

Abstract

The short- and long-term creep behaviors of ultra-high-molecular-weight polyethylene (UHMWPE) systems (compression-molded UHMWPE sheets and self-reinforced UHMWPE composites) have been investigated. The short-term (30-120 min) creep experiment was conducted at a load of 1 MPa and a temperature range of 37-62 degrees C. Based on short-term creep data, the long-term creep behavior of UHMWPE systems at 1 MPa and 37 degrees C was predicted using time-temperature superposition and analytical formulas. Compared to actual long-term creep experiments of up to 110 days, the predicted creep values were found to well describe the creep properties of the materials. The creep behaviors of the UHMWPE systems were then evaluated for a creep time of longer than 10 years, and it was found that most creep deformation occurs in the early periods. The shift factors associated with time-temperature superposition were found to increase with increasing temperature, as per the Arrhenius equation. The effects of temperature, materials, and load on the shift factors could be explained by the classical free volume theory.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9549616     DOI: 10.1002/(sici)1097-4636(199805)40:2<214::aid-jbm6>3.0.co;2-o

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  6 in total

1.  Quantification of clearance and creep in acetabular wear measurements.

Authors:  Mo Saffarini; Thomas Gregory; Eric Vandenbussche
Journal:  Ann Transl Med       Date:  2016-04

2.  HDPE/UHMWPE hybrid nanocomposites with surface functionalized graphene oxide towards improved strength and cytocompatibility.

Authors:  Shardul Atul Bhusari; Vidushi Sharma; Suryasarathi Bose; Bikramjit Basu
Journal:  J R Soc Interface       Date:  2019-01-31       Impact factor: 4.118

Review 3.  A Review on Biomaterials for Orthopaedic Surgery and Traumatology: From Past to Present.

Authors:  Grzegorz Szczęsny; Mateusz Kopec; Denis J Politis; Zbigniew L Kowalewski; Adam Łazarski; Tomasz Szolc
Journal:  Materials (Basel)       Date:  2022-05-18       Impact factor: 3.748

4.  A Highly Backdrivable, Lightweight Knee Actuator for Investigating Gait in Stroke.

Authors:  James S Sulzer; Ronald A Roiz; Michael A Peshkin; James L Patton
Journal:  IEEE Trans Robot       Date:  2009-06       Impact factor: 5.567

5.  Long-term in vivo wear of different bearing types used for the Oxford Unicompartmental Knee Replacement.

Authors:  Hasan R Mohammad; Stefano Campi; James A Kennedy; Andrew Judge; David W Murray; Stephen J Mellon
Journal:  Bone Joint Res       Date:  2019-12-03       Impact factor: 5.853

6.  Surgical cup placement affects the heating up of total joint hip replacements.

Authors:  Philipp Damm; Alwina Bender; Vivian Waldheim; Tobias Winkler; Georg N Duda
Journal:  Sci Rep       Date:  2021-08-04       Impact factor: 4.379

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.