Literature DB >> 9545932

Root canal cleanliness after preparation with different endodontic handpieces and hand instruments: a comparative SEM investigation.

M Hülsmann1, C Rümmelin, F Schäfers.   

Abstract

The root canals of 150 extracted mandibular incisors were prepared to ISO 30 using eight different automated devices and hand instruments. The automated devices investigated were: Endoplaner, Excalibur, Ultrasonics (Piezon Master 400) with H2O2 (5%), or NaOCl (1%) as irrigants, Giromatic, Intra-Endo 3-LDSY, Canal Finder System, Canal Leader 2000, and Endolift. Hand instrumentation was performed using reamers and Hedstroem files. Fifteen teeth were instrumented with each device, cracked longitudinally, and investigated under the scanning electron microscope using five category scoring systems based on reference photographs for debris and smear layer. No preparation system or technique resulted in complete removal of smear layer and debris. The ultrasonic unit performed best followed by the Canal Leader 2000 and hand instrumentation, whereas the use of the Giromatic, the Endolift, the Canal Finder System, and the Intra-Endo-3-LDSY-handpiece resulted in insufficiently cleaned root canal walls.

Entities:  

Mesh:

Year:  1997        PMID: 9545932     DOI: 10.1016/S0099-2399(97)80410-4

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  71 in total

1.  Effectiveness of the erbium:YAG laser and new design radial and stripped tips in removing the smear layer after root canal instrumentation.

Authors:  E DiVito; O A Peters; G Olivi
Journal:  Lasers Med Sci       Date:  2010-12-01       Impact factor: 3.161

2.  Smear Layer Evaluation on Root Canal Preparation with Manual and Rotary Techniques using EDTA as an Irrigant: A Scanning Electron Microscopy Study.

Authors:  M Manjunatha; Kini Annapurna; V Sudhakar; Vc Sunil Kumar; Vinay Kumar Hiremath; Ankur Shah
Journal:  J Int Oral Health       Date:  2013-02-26

3.  The effect of final irrigation on the penetrability of an epoxy resin-based sealer into dentinal tubules: a confocal microscopy study.

Authors:  Alexander Pompermayer Jardine; Ricardo Abreu da Rosa; Manuela Favarin Santini; Márcia Wagner; Marcus Vinícius Reis Só; Milton Carlos Kuga; Jefferson Ricardo Pereira; Patrícia Maria Poli Kopper
Journal:  Clin Oral Investig       Date:  2015-04-24       Impact factor: 3.573

4.  Scanning Electron Microscopic Evaluation of Root Canal Surfaces Prepared with LightSpeed & Endowave Rotary System.

Authors:  Hema B S; G S Chandu; Vijayakumar L Shiraguppi
Journal:  J Clin Diagn Res       Date:  2014-12-05

5.  Smear layer removal and sealer penetration with different tapers after using photon-initiated photoacoustic streaming technique.

Authors:  Islam Mohamed Eldeeb; Nawar Naguib Nawar; Shehabeldin Mohamed Saber; Ehab El-Sayed Hassanein; Edgar Schäfer
Journal:  Clin Oral Investig       Date:  2021-02-04       Impact factor: 3.573

6.  The effectiveness of the Erbium:Yttrium aluminum garnet PIPS technique in comparison to different chemical solutions in removing the endodontic smear layer-an in vitro profilometric study.

Authors:  Riman Nasher; Rene Franzen; Norbert Gutknecht
Journal:  Lasers Med Sci       Date:  2016-10-24       Impact factor: 3.161

7.  Canal cleanliness using different irrigation activation systems: a SEM evaluation.

Authors:  K Urban; D Donnermeyer; Edgar Schäfer; S Bürklein
Journal:  Clin Oral Investig       Date:  2017-02-09       Impact factor: 3.573

8.  F360 and F6 Skytaper: SEM evaluation of cleaning efficiency.

Authors:  Alberto Dagna; Giulia Gastaldo; Riccardo Beltrami; Marco Chiesa; Claudio Poggio
Journal:  Ann Stomatol (Roma)       Date:  2016-02-12

9.  CT evaluation of canal preparation using rotary and hand NI-TI instruments: An in vitro study.

Authors:  Shruthi Nagaraja; B V Sreenivasa Murthy
Journal:  J Conserv Dent       Date:  2010-01

10.  Comparative evaluation of surface characteristics of dentinal walls with and without using plastic finishing file.

Authors:  Smita Singh; Neeraj Nigam
Journal:  J Conserv Dent       Date:  2010-04
View more