Literature DB >> 9543420

Gradient characterization using a Fourier-transform technique.

M T Alley1, G H Glover, N J Pelc.   

Abstract

This paper describes a technique for characterizing the gradient subsystem of a magnetic resonance (MR) system. The technique uses a Fourier-transform analysis to directly measure the k-space trajectory produced by an arbitrary gradient waveform. In addition, the method can be easily extended to multiple dimensions and can be adapted to measuring residual gradient effects such as eddy currents. Several examples of gradient waveform and eddy-current measurements are presented. Also, it is demonstrated how the eddy-current measurements can be parameterized with an impulse-response formalism for later use in system tuning. When compared to a peak-fitting analysis, this technique provides a more direct extraction of the k-space measurements, which reduces the possibility of analysis error. This approach also has several advantages as compared to the conventional eddy-current measurement technique, including the ability to measure very short time constant effects.

Mesh:

Year:  1998        PMID: 9543420     DOI: 10.1002/mrm.1910390411

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  12 in total

1.  MODEL-BASED IMAGE RECONSTRUCTION FOR MRI.

Authors:  Jeffrey A Fessler
Journal:  IEEE Signal Process Mag       Date:  2010-07-01       Impact factor: 12.551

2.  Estimation of k-space trajectories in spiral MRI.

Authors:  Hao Tan; Craig H Meyer
Journal:  Magn Reson Med       Date:  2009-06       Impact factor: 4.668

3.  Improved half RF slice selectivity in the presence of eddy currents with out-of-slice saturation.

Authors:  Sonal Josan; Elena Kaye; John M Pauly; Bruce L Daniel; Kim Butts Pauly
Journal:  Magn Reson Med       Date:  2009-05       Impact factor: 4.668

4.  Iterative method for predistortion of MRI gradient waveforms.

Authors:  Kevin D Harkins; Mark D Does; William A Grissom
Journal:  IEEE Trans Med Imaging       Date:  2014-04-29       Impact factor: 10.048

5.  MR-based PET attenuation correction using a combined ultrashort echo time/multi-echo Dixon acquisition.

Authors:  Paul Kyu Han; Debra E Horng; Kuang Gong; Yoann Petibon; Kyungsang Kim; Quanzheng Li; Keith A Johnson; Georges El Fakhri; Jinsong Ouyang; Chao Ma
Journal:  Med Phys       Date:  2020-05-11       Impact factor: 4.071

6.  Impact of gradient imperfections on bone water quantification with UTE MRI.

Authors:  Xia Zhao; Hyunyeol Lee; Hee Kwon Song; Cheng-Chieh Cheng; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2020-04-19       Impact factor: 4.668

7.  Dynamic and high-resolution metabolic imaging of hyperpolarized [1-13C]-pyruvate in the rat brain using a high-performance gradient insert.

Authors:  Dirk Mayer; Yi-Fen Yen; Atsushi Takahashi; Sonal Josan; James Tropp; B K Rutt; Ralph E Hurd; Daniel M Spielman; Adolf Pfefferbaum
Journal:  Magn Reson Med       Date:  2010-11-30       Impact factor: 4.668

8.  Parallel excitation in the human brain at 9.4 T counteracting k-space errors with RF pulse design.

Authors:  Xiaoping Wu; J Thomas Vaughan; Kâmil Uğurbil; Pierre-François Van de Moortele
Journal:  Magn Reson Med       Date:  2010-02       Impact factor: 4.668

9.  Self-Navigated Three-Dimensional Ultrashort Echo Time Technique for Motion-Corrected Skull MRI.

Authors:  Hyunyeol Lee; Xia Zhao; Hee Kwon Song; Felix W Wehrli
Journal:  IEEE Trans Med Imaging       Date:  2020-03-04       Impact factor: 10.048

10.  Efficient gradient waveform measurements with variable-prephasing.

Authors:  Kevin D Harkins; Mark D Does
Journal:  J Magn Reson       Date:  2021-02-20       Impact factor: 2.734

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.