Literature DB >> 9543292

Eleven peak flow meters: a clinical evaluation.

H Folgering1, W vd Brink, O v Heeswijk, C v Herwaarden.   

Abstract

Peak flow meters are essential tools in the management of asthma. Many types are on the market. A computer-driven piston pump is normally not available for evaluation of the various meters. Comparison with values from a pneumotachograph is an accepted way of testing peak flow meters. This study aims at comparing 11 peak flow meters, for accuracy and linearity. Seven adult peak flow meters were tested: Miniwright with an equidistant scale (Clement Clarke); Personal Best (Healthscan); Wright Pocket fdE (Ferraris); Vitalograph (Vitalograph); Assess (Healthscan); Pocket Peak flow meter (Micro Medical); and Truzone (Monaghan). Furthermore, four low-range (LR) peak flow meters were tested: LR Miniwright with equidistant scale (Clement Clarke); LR Personal Best (Healthscan); LR Wright Pocket (LR Ferraris); and LR Pocket peak flow meter (LR Micro Medical). Two test series were performed: in the first one, a peak flow meter was connected downstream in series with a Fleisch #4 pneumotachograph. One subject performed 50 partial forced expiratory manoeuvres through this ensemble. In the second series, 50 adult patients and 25 healthy children performed sequential maximal forced expiratory manoeuvres on each peak flow meter, and on the pneumotachograph. A ranking system was devised for the various parameters of agreement of the meters with the pneumotachograph. Substantial differences in the quality of the adult meters were found. The adult peak flow meters with the closest agreement to the pneumotachograph were Personal Best and Micro Medical. In the low-range peak flow meters, the lowest differences were seen in the LR Personal Best and LR Micro Medical.

Entities:  

Mesh:

Year:  1998        PMID: 9543292     DOI: 10.1183/09031936.98.11010188

Source DB:  PubMed          Journal:  Eur Respir J        ISSN: 0903-1936            Impact factor:   16.671


  3 in total

1.  Randomised controlled study of clinical efficacy of spacer therapy in asthma with regard to electrostatic charge.

Authors:  E Dompeling; A M Oudesluys-Murphy; H M Janssens; W Hop; J G Brinkman; R N Sukhai; J C de Jongste
Journal:  Arch Dis Child       Date:  2001-02       Impact factor: 3.791

2.  National Athletic Trainers' Association position statement: management of asthma in athletes.

Authors:  Michael G Miller; John M Weiler; Robert Baker; James Collins; Gilbert D'Alonzo
Journal:  J Athl Train       Date:  2005 Jul-Sep       Impact factor: 2.860

3.  Comparison of five portable peak flow meters.

Authors:  Glaucia Nency Takara; Gualberto Ruas; Bruna Varanda Pessoa; Luciana Kawakami Jamami; Valéria Amorim Pires Di Lorenzo; Mauricio Jamami
Journal:  Clinics (Sao Paulo)       Date:  2010-05       Impact factor: 2.365

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.