Literature DB >> 954317

Pathological human synovial fluids. Viscosity and boundary lubricating properties.

I Reimann.   

Abstract

On human synovial fluids obtained during operations from the knee joints of 80 patients with different joing disease, relative viscosity was measured at 3 different shear rates and the boundary lubrication was tested by the coefficient of friction in an artificial rubber/glass system. The results were evaluated in relation to the operative findings. The viscosity showed statistically significant differences between the synovial fluids from the knee joints with rheumatoid arthritis, osteoarthritis, and torn menisci, being lowest in rheumatoid synovial fluid and highest in synovial fluids from knee joints with torn menisci. Correlations were found in the variations in the viscosity and the degree of synovitis. The boundary lubrication also showed different values inrelation to the different diseases. Synovial fluid from knee joints with torn menisci seemed to act as the best lubricant and significantly better than rheumatoid synovial fluid. Variations in the boundary lubrications reflect successive degrees of cartilage degeneration.

Entities:  

Mesh:

Year:  1976        PMID: 954317

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  5 in total

Review 1.  Microfluidic viscometers for shear rheology of complex fluids and biofluids.

Authors:  Siddhartha Gupta; William S Wang; Siva A Vanapalli
Journal:  Biomicrofluidics       Date:  2016-07-05       Impact factor: 2.800

2.  Effects of equine joint injury on boundary lubrication of articular cartilage by synovial fluid: role of hyaluronan.

Authors:  Jennifer M Antonacci; Tannin A Schmidt; Lisa A Serventi; Matthew Z Cai; YuYu L Shu; Barbara L Schumacher; C Wayne McIlwraith; Robert L Sah
Journal:  Arthritis Rheum       Date:  2012-09

3.  Macroscopic assessment of cartilage shear: effects of counter-surface roughness, synovial fluid lubricant, and compression offset.

Authors:  Quynhhoa T Nguyen; Benjamin L Wong; June Chun; Yeoung C Yoon; Frank E Talke; Robert L Sah
Journal:  J Biomech       Date:  2010-03-01       Impact factor: 2.712

4.  In vivo quantification of lymph viscosity and pressure in lymphatic vessels and draining lymph nodes of arthritic joints in mice.

Authors:  Echoe M Bouta; Ronald W Wood; Edward B Brown; Homaira Rahimi; Christopher T Ritchlin; Edward M Schwarz
Journal:  J Physiol       Date:  2014-01-13       Impact factor: 5.182

5.  The wettability of electron spun membranes by synovial fluid.

Authors:  Ales Hrouda; Radek Jirkovec; Petra Hamrikova; Maarten Vanierschot; Kathleen Denis; Lukas Capek
Journal:  R Soc Open Sci       Date:  2021-12-22       Impact factor: 2.963

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.