Literature DB >> 9541829

Exchange of perfluorodecalin for gas or oil: a model for avoiding slippage.

D Wong1, R L Williams, M J German.   

Abstract

BACKGROUND: The introduction of liquid perfluorocarbons as an intraoperative tool has greatly facilitated retinal re-apposition in giant retinal tears (GRT) and relieving retinotomies (RR). Slippage of the retina can occur during the exchange of heavy liquids for oil or gas, especially if the fill of perfluorocarbons is subtotal.
METHODS: We have used a model eye chamber to study the surface interactions of perfluorodecalin (PFD) with silicone oil and air to evaluate possible mechanisms of slippage.
RESULTS: The results demonstrate that it is possible during a PFD/air exchange to trap a wedge of aqueous which is displaced laterally and forced posteriorly during removal of the PFD, whereas during a PFD/silicone oil exchange the remaining aqueous is displaced laterally and upwards and thus trapped above the silicone oil/PFD interface.
CONCLUSIONS: We believe that during PFD/air exchange the displacement of the aqueous posteriorly can cause slippage and that this could be avoided by performing a direct PFD/silicone oil exchange.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9541829     DOI: 10.1007/s004170050070

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  9 in total

1.  Avoiding retinal slippage during macular translocation surgery with 360 retinotomy.

Authors:  Kenneth K W Li; David Wong
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2007-11-15       Impact factor: 3.117

2.  An experimental study on the effect of encircling band procedure on silicone oil emulsification.

Authors:  D J de Silva; K S Lim; W E Schulenburg
Journal:  Br J Ophthalmol       Date:  2005-10       Impact factor: 4.638

3.  Tamponade properties of double-filling with perfluorohexyloctane and silicone oil in a model eye chamber.

Authors:  Edward Herbert; Theodor Stappler; Carolina Wetterqvist; Rachel Williams; David Wong
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2003-12-18       Impact factor: 3.117

4.  Management of a unique case of post-traumatic posterior giant retinal tear and macular hole-associated rhegmatogenous retinal detachment.

Authors:  Ramanuj Samanta; Gitanjli Sood; Shalaka R Waghamare; Raghavendra R Mareguddi; Sanjeev K Mittal; Ajai Agrawal
Journal:  Indian J Ophthalmol       Date:  2020-11       Impact factor: 1.848

5.  Tamponade efficiency of perfluorohexyloctane and silicone oil solutions in a model eye chamber.

Authors:  C Wetterqvist; D Wong; R Williams; T Stappler; E Herbert; S Freeburn
Journal:  Br J Ophthalmol       Date:  2004-05       Impact factor: 4.638

Review 6.  [Heavy liquids as intraoperative instrument in retinal surgery].

Authors:  Karl Boden; K Januschowski; P Szurman
Journal:  Ophthalmologe       Date:  2019-10       Impact factor: 1.059

7.  The phenomenon of "sticky" silicone oil.

Authors:  Joachim H Dresp; Dirk-Henning Menz
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-11-22       Impact factor: 3.535

8.  Fully Automated Direct Perfluorocarbon Liquid-Silicone Oil Exchange.

Authors:  Kinza T Ahmad; Ahmed B Sallam; Ahmed A Saad; Abdallah A Ellabban
Journal:  Clin Ophthalmol       Date:  2020-12-10

9.  A case of silicone oil adhered to the retinal surface via perfluorocarbon liquid.

Authors:  Masanori Fukumoto; Yui Nishida; Teruyo Kida; Takaki Sato; Takatoshi Kobayashi; Tsunehiko Ikeda
Journal:  BMC Ophthalmol       Date:  2018-03-27       Impact factor: 2.209

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.