Literature DB >> 9541439

Influence of dorzolamide on corneal thickness, endothelial cell count and corneal sensibility.

S Kaminski1, A Hommer, D Koyuncu, R Biowski, T Barisani, I Baumgartner.   

Abstract

PURPOSE: Dorzolamide (Trusopt) is the first topical carbonic anhydrase inhibitor (CAI) that is in clinical use in glaucoma therapy. It is known that CAI have a negative effect on corneal endothelial pumpfunction and therefore on the whole corneal physiology.
METHODS: 20 patients with open angle glaucoma or ocular hypertension and an elevated intraocular pressure (IOP) over 21 mmHg and without prior oral CAI-treatment were included in this study. Trusopt was administered t.i.d. as monotherapy and b.i.d. in combination with other topical antiglaucoma drugs. Corneal ultrasound pachymetry, corneal endothelial cell count and aesthesiometry were performed prestudy and on days 1, 8, 15, 30, 60 and 90. RESULTS AND
CONCLUSIONS: Mean corneal thickness was slightly increased on day one (statistically non-significant) and returned to baseline measurements at the following visits, no changes in endothelial cell count and corneal anesthesia were found. Topical dorzolamide is not associated with clinically meaningful changes of the cornea.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9541439     DOI: 10.1034/j.1600-0420.1998.760114.x

Source DB:  PubMed          Journal:  Acta Ophthalmol Scand        ISSN: 1395-3907


  12 in total

1.  Knockdown of NBCe1 in vivo compromises the corneal endothelial pump.

Authors:  Cailing Liu; Qiang Cheng; Tracy Nguyen; Joseph A Bonanno
Journal:  Invest Ophthalmol Vis Sci       Date:  2010-05-05       Impact factor: 4.799

Review 2.  Pharmacological therapy for glaucoma: a review.

Authors:  P F Hoyng; L M van Beek
Journal:  Drugs       Date:  2000-03       Impact factor: 9.546

Review 3.  Corneal Endothelial Cell Loss in Glaucoma and Glaucoma Surgery and the Utility of Management with Descemet Membrane Endothelial Keratoplasty (DMEK).

Authors:  Neeru A Vallabh; Stephnie Kennedy; Riccardo Vinciguerra; Keri McLean; Hannah Levis; Davide Borroni; Vito Romano; Colin E Willoughby
Journal:  J Ophthalmol       Date:  2022-01-30       Impact factor: 1.974

4.  Role of carbonic anhydrase IV in corneal endothelial HCO3- transport.

Authors:  Xing Cai Sun; Jinhua Li; Miao Cui; Joseph A Bonanno
Journal:  Invest Ophthalmol Vis Sci       Date:  2008-03       Impact factor: 4.799

5.  Repeatability of the Novel Intraocular Pressure Measurement From Corvis ST.

Authors:  Masato Matsuura; Hiroshi Murata; Yuri Fujino; Mieko Yanagisawa; Yoshitaka Nakao; Shunsuke Nakakura; Yoshiaki Kiuchi; Ryo Asaoka
Journal:  Transl Vis Sci Technol       Date:  2019-06-24       Impact factor: 3.283

6.  The Relationship between Corvis ST Tonometry Measured Corneal Parameters and Intraocular Pressure, Corneal Thickness and Corneal Curvature.

Authors:  Ryo Asaoka; Shunsuke Nakakura; Hitoshi Tabuchi; Hiroshi Murata; Yoshitaka Nakao; Noriko Ihara; Ulfah Rimayanti; Makoto Aihara; Yoshiaki Kiuchi
Journal:  PLoS One       Date:  2015-10-20       Impact factor: 3.240

7.  The Relationship between Corvis ST Tonometry and Ocular Response Analyzer Measurements in Eyes with Glaucoma.

Authors:  Masato Matsuura; Kazunori Hirasawa; Hiroshi Murata; Mieko Yanagisawa; Yoshitaka Nakao; Shunsuke Nakakura; Yoshiaki Kiuchi; Ryo Asaoka
Journal:  PLoS One       Date:  2016-08-31       Impact factor: 3.240

8.  The usefulness of CorvisST Tonometry and the Ocular Response Analyzer to assess the progression of glaucoma.

Authors:  Masato Matsuura; Kazunori Hirasawa; Hiroshi Murata; Shunsuke Nakakura; Yoshiaki Kiuchi; Ryo Asaoka
Journal:  Sci Rep       Date:  2017-01-17       Impact factor: 4.379

9.  Evaluation of corneal endothelium in adolescents with juvenile glaucoma.

Authors:  Beata Urban; Alina Bakunowicz-Łazarczyk; Marta Michalczuk; Małgorzata Krętowska
Journal:  J Ophthalmol       Date:  2015-01-06       Impact factor: 1.909

10.  Association between Corneal Biomechanical Properties with Ocular Response Analyzer and Also CorvisST Tonometry, and Glaucomatous Visual Field Severity.

Authors:  Kazunori Hirasawa; Masato Matsuura; Hiroshi Murata; Shunsuke Nakakura; Yoshitaka Nakao; Yoshiaki Kiuchi; Ryo Asaoka
Journal:  Transl Vis Sci Technol       Date:  2017-06-14       Impact factor: 3.283

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.