Interrupted expiratory flow on automatically constructed flow-volume curves may determine the presence of intrinsic positive end-expiratory pressure during one-lung ventilation.

G I Bardoczky1, A A d'Hollander, M Cappello, J C Yernault.   

Abstract

UNLABELLED: We studied patients undergoing elective pulmonary surgery to establish whether observing interrupted expiratory flow (IEF) on the flow-volume curves constructed by the Ultima SV respiratory monitor is a reliable way to identify patients with dynamic pulmonary hyperinflation and intrinsic positive end-expiratory pressure (PEEPi). Patients' tracheas were intubated with a double-lumen endotracheal tube and ventilated with a Siemens 900C constant flow ventilator. In 30 patients, PEEPi was determined by the end-expiratory occlusion (EEO) method during the periods of two-lung and one-lung ventilation in the lateral position. Sensitivity, specificity, positive and negative predictive values, and diagnostic accuracy of the IEF method were calculated. From the 122 measurement pairs, PEEPi was identified with the EEO method in 65 occasions. The mean level of PEEPi was 4.4 cm H2O. During one-lung ventilation, the level of PEEPi and the number of true-positive findings was significantly higher (PEEPi = 4.7 cm H2O and 32 episodes) than during two-lung ventilation (2.9 cm H2O and 19 episodes). When the level of PEEPi was higher than 5 cm H2O, the predictive value of IEF was 100%. The overall sensitivity of the IEF method was 0.78, its specificity was 0.91, and its predictive value was 0.92. In conclusion, examination of the flow-volume curves displayed on the respiratory monitor may identify patients with dynamic hyperinflation and PEEPi during anesthesia for thoracic surgery. IMPLICATIONS: To identify patients with intrinsic positive end-expiratory pressure during anesthesia without the need to interrupt mechanical ventilation, the flow-volume curves of an online respiratory monitor may be examined. The presence of an interrupted expiratory flow may suggest the presence of intrinsic positive end-expiratory pressure with a reasonable accuracy.

Entities:  

Mesh:

Year:  1998        PMID: 9539619     DOI: 10.1097/00000539-199804000-00037

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  5 in total

1.  Monitoring of vecuronium-induced neuromuscular blockade during one-lung ventilation.

Authors:  Yuhji Saitoh; Tsutomu Oshima; Yoshinori Nakata
Journal:  J Anesth       Date:  2008-11-15       Impact factor: 2.078

Review 2.  Assessment and monitoring of flow limitation and other parameters from flow/volume loops.

Authors:  R Dueck
Journal:  J Clin Monit Comput       Date:  2000       Impact factor: 2.502

3.  Adjusting tidal volume to stress index in an open lung condition optimizes ventilation and prevents overdistension in an experimental model of lung injury and reduced chest wall compliance.

Authors:  Carlos Ferrando; Fernando Suárez-Sipmann; Andrea Gutierrez; Gerardo Tusman; Jose Carbonell; Marisa García; Laura Piqueras; Desamparados Compañ; Susanie Flores; Marina Soro; Alicia Llombart; Francisco Javier Belda
Journal:  Crit Care       Date:  2015-01-13       Impact factor: 9.097

4.  Volume-Controlled Versus Dual-Controlled Ventilation during Robot-Assisted Laparoscopic Prostatectomy with Steep Trendelenburg Position: A Randomized-Controlled Trial.

Authors:  Jin Ha Park; In Kyeong Park; Seung Ho Choi; Darhae Eum; Min-Soo Kim
Journal:  J Clin Med       Date:  2019-11-21       Impact factor: 4.241

Review 5.  Effect of the Prolonged Inspiratory to Expiratory Ratio on Oxygenation and Respiratory Mechanics During Surgical Procedures.

Authors:  Jin Ha Park; Jong Seok Lee; Jae Hoon Lee; Seokyung Shin; Nar Hyun Min; Min-Soo Kim
Journal:  Medicine (Baltimore)       Date:  2016-03       Impact factor: 1.889