Literature DB >> 9538713

Core body temperature measurement: a comparison of axilla, tympanic membrane and pulmonary artery blood temperature.

P Fulbrook1.   

Abstract

This research study was undertaken to examine the relationship between pulmonary artery blood temperature (regarded as the 'gold standard' measurement for core body temperature), axilla temperature using the Tempa.DOT Ax chemical thermometer and tympanic membrane temperature using the Diatek 9000 InstaTemp thermometer. Sixty adult intensive care patients had their temperatures monitored. A single set of five simultaneous temperatures, i.e. left and right axilla, left and right tympanic membrane (TM), and pulmonary artery (PA) blood were recorded. The mean difference between left and right TM temperatures was 0.58 degree C, and although both were moderately well correlated with PA temperature (r = 0.63 and 0.78, respectively) the mean differences between the two sites were clinically significant (0.85 degree C and 0.94 degree C, respectively). The range of differences between the sites was significant. Plotting limits of agreement showed that both left and right TM temperatures may be up to 1.2 degrees C above or 1.3 degrees C below PA blood temperature: a clinically unacceptable range. In particular, large temperature differences were recorded when patients were lying with one side of their head to a pillow. Fan therapy directed to the head was not found to affect these differences significantly. The mean difference between left and right axilla temperatures was 0.36 degree C, and although both were modestly correlated with PA temperature (r = 0.48 and 0.53, respectively) the mean differences between the two sites were clinically significant (0.47 degree C and 0.50 degree C, respectively). The range of differences between the sites was particularly significant. Plotting limits of agreement showed that both left and right axilla temperatures may be up to 1.2 degrees C above or 1.6 degrees C below PA blood temperature: a clinically unacceptable range. Because the range of temperature differences found between PA blood and the other sites was so great, it is concluded that neither the chemical axilla thermometer nor the tympanic membrane thermometer used in this study are clinically reliable tools for adult intensive care patients.

Entities:  

Mesh:

Year:  1997        PMID: 9538713     DOI: 10.1016/s0964-3397(97)80425-9

Source DB:  PubMed          Journal:  Intensive Crit Care Nurs        ISSN: 0964-3397            Impact factor:   3.072


  12 in total

1.  Core-temperature sensor ingestion timing and measurement variability.

Authors:  Joseph W Domitrovich; John S Cuddy; Brent C Ruby
Journal:  J Athl Train       Date:  2010 Nov-Dec       Impact factor: 2.860

2.  Towards a non-invasive interictal application of hypothermia for treating seizures: a feasibility and pilot study.

Authors:  A Bagić; W H Theodore; E A Boudreau; R Bonwetsch; J Greenfield; W Elkins; S Sato
Journal:  Acta Neurol Scand       Date:  2008-03-18       Impact factor: 3.209

3.  Altered circadian rhythmicity in patients in the ICU.

Authors:  Joost A C Gazendam; Hans P A Van Dongen; Devon A Grant; Neil S Freedman; Jan H Zwaveling; Richard J Schwab
Journal:  Chest       Date:  2013-08       Impact factor: 9.410

4.  Comparability of tympanic and oral mercury thermometers at high ambient temperatures.

Authors:  Amy L Chue; Rachael L Moore; Andrew Cavey; Elizabeth A Ashley; Kasia Stepniewska; François Nosten; Rose McGready
Journal:  BMC Res Notes       Date:  2012-07-16

Review 5.  Evidence-based guidelines for empirical therapy of neutropenic fever in Korea.

Authors:  Dong-Gun Lee; Sung-Han Kim; Soo Young Kim; Chung-Jong Kim; Wan Beom Park; Young Goo Song; Jung-Hyun Choi
Journal:  Korean J Intern Med       Date:  2011-06-01       Impact factor: 3.165

Review 6.  Re-visiting the tympanic membrane vicinity as core body temperature measurement site.

Authors:  Wui Keat Yeoh; Jason Kai Wei Lee; Hsueh Yee Lim; Chee Wee Gan; Wenyu Liang; Kok Kiong Tan
Journal:  PLoS One       Date:  2017-04-17       Impact factor: 3.240

7.  Reexamining age, race, site, and thermometer type as variables affecting temperature measurement in adults - A comparison study.

Authors:  Linda S Smith
Journal:  BMC Nurs       Date:  2003-06-15

8.  Accidental cold-related injury leading to hospitalization in northern Sweden: an eight-year retrospective analysis.

Authors:  Helge Brändström; Göran Johansson; Gordon G Giesbrecht; Karl-Axel Ängquist; Michael F Haney
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2014-01-27       Impact factor: 2.953

9.  Emergency department rectal temperatures in over 10 years: A retrospective observational study.

Authors:  Graham A Walker; Daniel Runde; Daniel M Rolston; Dan Wiener; Jarone Lee
Journal:  World J Emerg Med       Date:  2013

10.  Temperature measurements in trauma patients: is the ear the key to the core?

Authors:  O Uleberg; S C Eidstuen; G Vangberg; E Skogvoll
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2015-11-19       Impact factor: 2.953

View more