Abstract

A method is suggested for quantitative flow assessment of whole-blood perfusing tubes with diameters in the range from 500 microns to 1.5 mm, for velocities below 9 mm s-1. The algorithm is based both on the Doppler broadening of backscattered laser light and the magnitude of the diameter of the perfused tube. A bandwidth-modified high-resolution laser Doppler perfusion imaging system is used to record the Doppler broadening. A flow model, consisting of a linearly narrowing tube (inner diameter 620-1330 microns), is connected to a precision infusion pump and perfused by human whole blood of volume flows ranging from 0 to 6.6 mm3 s-1. Empirical data are fitted into a regression model, and the parameters of the algorithm can be determined, resulting in a correlation coefficient of 0.975 between the predicted and true volume flows. Using this algorithm, volume flows in tubes of inner diameters of 500 microns, 750 microns and 1.4 mm are predicted, with accuracies corresponding to correlation coefficients of 0.994, 0.993 and 0.996.

Entities:  

Mesh:

Year:  1997        PMID: 9538531     DOI: 10.1007/bf02510963

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  14 in total

1.  Measurement of regional circulation by the local clearance of radioactive sodium.

Authors:  S S KETY
Journal:  Am Heart J       Date:  1949-09       Impact factor: 4.749

2.  Atraumatic local labeling of skin by inert gas: epicutaneous application of xenon 133.

Authors:  P Sejrsen
Journal:  J Appl Physiol       Date:  1968-04       Impact factor: 3.531

3.  Velocity measurements in the microvasculature of the cat omentum by on-line method.

Authors:  M Intaglietta; W R Tompkins; D R Richardson
Journal:  Microvasc Res       Date:  1970-10       Impact factor: 3.514

4.  Changes in skin circulation after insertion of a microdialysis probe visualized by laser Doppler perfusion imaging.

Authors:  C Anderson; T Andersson; K Wårdell
Journal:  J Invest Dermatol       Date:  1994-05       Impact factor: 8.551

5.  The cutaneous vascular axon reflex in humans characterized by laser Doppler perfusion imaging.

Authors:  K Wårdell; H K Naver; G E Nilsson; B G Wallin
Journal:  J Physiol       Date:  1993-01       Impact factor: 5.182

6.  In vitro comparison of different signal processing algorithms used in laser Doppler flowmetry.

Authors:  A N Obeid
Journal:  Med Biol Eng Comput       Date:  1993-01       Impact factor: 2.602

7.  Spatial heterogeneity in normal skin perfusion recorded with laser Doppler imaging and flowmetry.

Authors:  K Wårdell; I M Braverman; D G Silverman; G E Nilsson
Journal:  Microvasc Res       Date:  1994-07       Impact factor: 3.514

8.  A new instrument for continuous measurement of tissue blood flow by light beating spectroscopy.

Authors:  G E Nilsson; T Tenland; P A Obert
Journal:  IEEE Trans Biomed Eng       Date:  1980-01       Impact factor: 4.538

9.  Evaluation of port wine stain perfusion by laser Doppler imaging and thermography before and after argon laser treatment.

Authors:  A Troilius; K Wårdell; S Bornmyr; G E Nilsson; B Ljunggren
Journal:  Acta Derm Venereol       Date:  1992       Impact factor: 4.437

10.  Laser-Doppler perfusion imaging of microvascular blood flow in rabbit tenuissimus muscle.

Authors:  M Lindén; A Sirsjö; L Lindbom; G Nilsson; A Gidlöf
Journal:  Am J Physiol       Date:  1995-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.