The aim of this study was to assess the use of an automatic filling system (Siframix M31 and M32 system) to prepare pediatric parenteral nutrition. Volumetric accuracy was measured for each siframix system loads cells (< 5% for 5 ml with the Siframix M32 and < 5% for 9 ml with the Siframix M31) with sterile water for injection. The minimal 20 ml of flushing sterile water of the common tubulure of the Siframix M32 (p = 0.211 for 20 ml and p = 0.75 for 500 ml), the use of viscous solutions (70% dextrose) on the Siframix M31 (p = 0.28 for 20 ml and p = 0.12 for 500 ml) and the use of a special tubulure for using E.V.A. Luer-lock bags (p = 0.89 for 20 ml and p = 0.103 for 500 ml) do not modify the accuracy. Changing bags or bottles during the filling operation modify the accuracy (p = 0.004 for 20 ml and p = 0.009 for 500 ml). A flushing operation is necessary to lower the risk of electrolytic pollution for the filling of little bags. The filling speed for each module was also measured (the maximal filling speed was five liters per minute). The Siframix system allows one to prepare pediatric parenteral nutrition bags when volumes are above 4 ml and with adapted source solutions in terms of concentration and conditioning volumes.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9536469     DOI: 10.1023/a:1008640426705

Source DB:  PubMed          Journal:  Pharm World Sci        ISSN: 0928-1231


  5 in total

1.  Effect of computer software on time required to prepare parenteral nutrient solutions.

Authors:  A M Seidel; T W Woller; S Somani; P W Abramowitz
Journal:  Am J Hosp Pharm       Date:  1991-02

2.  Automated compounder for adding ingredients to parenteral nutrient base solutions.

Authors:  L B Dickson; S M Somani; G Herrmann; P W Abramowitz
Journal:  Am J Hosp Pharm       Date:  1993-04

3.  Ensuring accuracy in the use of automatic compounders.

Authors:  C Murphy
Journal:  Am J Hosp Pharm       Date:  1993-01

4.  Specific gravity-based determination of dextrose content of total parenteral nutrient solutions for neonates.

Authors:  J M Silverberg; B Webb; R Pawlak
Journal:  Am J Hosp Pharm       Date:  1993-10

5.  Calcium and phosphorus compatibility in parental nutrition solutions for neonates.

Authors:  L D Eggert; W J Rusho; M W MacKay; G M Chan
Journal:  Am J Hosp Pharm       Date:  1982-01
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.