Abstract

PATIENTS AND METHODS: Between 1971 and 1993, 656 conduits were placed in the subpulmonary position. Patients receiving heterografts or valveless conduits and patients dying within 90 days of insertion were excluded; thus 405 homograft conduits were studied. There were 293 aortic homografts, 94 pulmonary, and 18 of unknown type. The end point of conduit failure was defined by conduit replacement for whatever reason, balloon dilation of the conduit, or death of the patient with the conduit in place. The following factors were analyzed: aortic versus pulmonary homograft, antibiotic preservation versus cryopreservation, ABO and Rh compatibility, type of material used for conduit extension, age at operation, size of the conduit, diagnosis, and reoperations. Conduit number (1 to 405) in the series was included in the multivariable model.
RESULTS: First conduits and conduits inserted earlier in the series appeared to last longer than second and subsequent conduits and those inserted later in the series (p = 0.001 and 0.003, respectively). Overall survival of conduits at 5, 10, and 15 years was 84% (95% CL, 80% to 88%), 58% (95% CL, 50% to 66%), and 31% (95% CL, 19% to 43%). Corresponding figures for the first conduits were 88% (95% CL, 84% to 92%), 65% (95% CL, 56% to 73%), and 34% (95% CL, 20% to 47%). The longest surviving homograft conduit in our series lasted 22.7 years. Regarded univariately, reoperation (redo worse), order number (recent worse), type of conduit (pulmonary worse than aortic), preservation (cryopreserved worse than antibiotic preserved), and age at operation (older patients worse) were statistically significant. However, in multivariable analysis, including all the above in the model, only reoperation and order number had significant predictive power. When patient survival was considered, patients operated on more recently survived longer despite the fact that their conduits were being replaced earlier. Overall, survival of patients at 5 and 15 years was 95% (95% CL, 93% to 98%) and 85% (95% CL, 77% to 92%), respectively.
CONCLUSIONS: Pulmonary and aortic homografts, both cryopreserved and preserved in nutrient antibiotic solution, give similar results. All conduits will probably have to be replaced during the lifetime of the patient. In view of the worse performance of replacement conduits, techniques of repair that avoid the use of conduits should be further explored. Despite gradual deterioration of homograft conduits, they remain an important tool in the correction of many complex lesions with excellent 15-year patient survival.

Entities:  

Mesh:

Year:  1998        PMID: 9535436     DOI: 10.1016/S0022-5223(98)70312-5

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  8 in total

Review 1.  Echocardiographic guidance for diagnostic and therapeutic percutaneous procedures.

Authors:  Cam Tu Nguyen; Eunice Lee; Huai Luo; Robert J Siegel
Journal:  Cardiovasc Diagn Ther       Date:  2011-12

2.  Systemic mechanical heart valve replacement in children under 16 years of age.

Authors:  A R Tiete; J S Sachweh; J Groetzner; H Gulbins; E G Muehler; B J Messmer; S H Daebritz
Journal:  Clin Res Cardiol       Date:  2006-05       Impact factor: 5.460

3.  Percutaneous pulmonary valve implantation as an alternative to repeat open-heart surgery for patients with pulmonary outflow obstruction: a reality in Singapore.

Authors:  Shakeel Ahmed Quereshi; Swee Chye Quek; Lik Wui Edgar Tay; Wei Luen James Yip; Ting Ting Low; Chin Ling William Yip; Kok Fai William Kong; Tiong Cheng Yeo; Huay Cheem Tan
Journal:  Singapore Med J       Date:  2018-11-29       Impact factor: 1.858

4.  Right ventricle to pulmonary artery conduit augmentation compared with replacement in young children.

Authors:  Justin P V Zachariah; Frank A Pigula; John E Mayer; Doff B McElhinney
Journal:  Ann Thorac Surg       Date:  2009-08       Impact factor: 4.330

5.  Functional collagen fiber architecture of the pulmonary heart valve cusp.

Authors:  Erinn M Joyce; Jun Liao; Frederick J Schoen; John E Mayer; Michael S Sacks
Journal:  Ann Thorac Surg       Date:  2009-04       Impact factor: 4.330

6.  Quantitative assessment of homograft function 1 year after insertion into the pulmonary position: impact of in situ homograft geometry on valve competence.

Authors:  Johannes Nordmeyer; Victor Tsang; Régis Gaudin; Philipp Lurz; Alessandra Frigiola; Alexander Jones; Silvia Schievano; Carin van Doorn; Philipp Bonhoeffer; Andrew M Taylor
Journal:  Eur Heart J       Date:  2009-06-04       Impact factor: 29.983

7.  Mid-term outcome of mechanical pulmonary valve prostheses: the importance of anticoagulation.

Authors:  Anita Sadeghpour; Majid Kyavar; Bahareh Javani; Hooman Bakhshandeh; Majid Maleki; Zahra Khajali; Lakshman Subrahmanyan
Journal:  J Cardiovasc Thorac Res       Date:  2014-09-30

8.  Percutaneous pulmonary valve implantation in patients with right ventricular outflow tract dysfunction: a systematic review and meta-analysis.

Authors:  Liyu Ran; Wuwan Wang; Francesco Secchi; Yajie Xiang; Wenhai Shi; Wei Huang
Journal:  Ther Adv Chronic Dis       Date:  2019-06-14       Impact factor: 5.091

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.