Literature DB >> 9533374

A standardized procedure for locating and documenting ECG chest electrode positions: consideration of the effect of breast tissue on ECG amplitudes in women.

P M Rautaharju1, L Park, F S Rautaharju, R Crow.   

Abstract

Continuing uncertainty exists about standardized procedures for the placement of electrocardiographic (ECG) chest electrodes, technical variability being the largest error source for short-term variations in amplitudes and waveforms of the chest lead ECGs. To avoid presumed attenuation of ECG amplitudes by abundant breast tissue, anterolateral chest electrodes in women are often placed under the breasts and too low. There is also considerable uncertainty about locating the midclavicular line and the V4 electrode, particularly in obese persons and in women. We examined the effect of breast tissue protuberance on ECG amplitudes using ECG and anthropometric data on 6,814 women included in the Atherosclerosis Research in Communities Study (ARIC). The R wave amplitudes in anterolateral chest leads and the Sokolow-Lyon voltage decreased (P < .001 for all), and RaVL and the Cornell voltage increased significantly with increasing breast protuberance (P < .001 for all). However, these effects were small (15 microV or less for each 1-cm increment in breast protuberance), and R2 values were less than .01, indicating that breast protuberance alone explained less than 1% of ECG amplitude variations. When chest size and breast protuberance estimates were entered simultaneously into a multivariate regression model, chest size appeared to dominate, and model R2 values increased for positive associations with RaVL (R2 = .12) and the Cornell voltage (R2 = .04). Combined model R2 values remained < or =.01 for all other ECG amplitudes. A detailed step-by-step standardized electrode placement procedure was formulated. Because of the difficulties encountered in locating the left midclavicular line by visual inspection, we introduced well-defined procedures for identification and documentation of lateral chest electrode placement locations as a quality control method for clinical trials. Population data from the Third National Health and Nutrition Survey on the distributions by sex and race of chest electrode V4 and V6 locations and anthropometric data on chest size and shape are presented in order to facilitate evaluation of the comparability of electrode placement procedures in various studies and for quality control in clinical trials. It is concluded that standardized procedures to document chest electrode placement locations are feasible. Breast tissue appears to have a practically negligible effect on ECG amplitudes, and in women, the placement of chest electrodes on the breast rather than under the breast is recommended in order to facilitate the precision of electrode placement at the correct horizontal level and at the correct lateral positions.

Entities:  

Mesh:

Year:  1998        PMID: 9533374     DOI: 10.1016/s0022-0736(98)90003-6

Source DB:  PubMed          Journal:  J Electrocardiol        ISSN: 0022-0736            Impact factor:   1.438


  23 in total

1.  Normal standards for computer-ECG programs for prognostically and diagnostically important ECG variables derived from a large ethnically diverse female cohort: the Women's Health Initiative (WHI).

Authors:  Pentti M Rautaharju; Zhu-ming Zhang; Richard E Gregg; Wesley K Haisty; Mara Z Vitolins; Anne B Curtis; James Warren; Milan B Horaĉek; Sophia H Zhou; Elsayed Z Soliman
Journal:  J Electrocardiol       Date:  2013-07-01       Impact factor: 1.438

Review 2.  Technical mistakes during the acquisition of the electrocardiogram.

Authors:  Javier García-Niebla; Pablo Llontop-García; Juan Ignacio Valle-Racero; Guillem Serra-Autonell; Velislav N Batchvarov; Antonio Bayés de Luna
Journal:  Ann Noninvasive Electrocardiol       Date:  2009-10       Impact factor: 1.468

3.  Precordial electrode placement in women.

Authors:  P W Macfarlane; R Colaco; K Stevens; P Reay; C Beckett; T Aitchison
Journal:  Neth Heart J       Date:  2003-03       Impact factor: 2.380

Review 4.  Main artifacts in electrocardiography.

Authors:  Andrés Ricardo Pérez-Riera; Raimundo Barbosa-Barros; Rodrigo Daminello-Raimundo; Luiz Carlos de Abreu
Journal:  Ann Noninvasive Electrocardiol       Date:  2017-09-20       Impact factor: 1.468

5.  Study on ECG in the Adolescent.

Authors:  Hung-Chi Lue; Mei-Hwan Wu; Jou-Kou Wang; Min-Tai Lin; Chun-Wei Lu; Shuenn-Nan Chiu; Chun-An Chen; En-Ting Wu; Ching-Chia Wang; Chun-Min Fu; Wei-Chien Tseng; Wei-Hsuan Chang; Meng-Chang Lee
Journal:  Pediatr Cardiol       Date:  2018-03-19       Impact factor: 1.655

6.  Electrocardiographic signs of left ventricular hypertrophy in obese patients: what criteria should be used?

Authors:  Giuseppe Germano
Journal:  High Blood Press Cardiovasc Prev       Date:  2014-08-05

7.  Variable association between components of the metabolic syndrome and electrocardiographic abnormalities in Korean adults.

Authors:  Hong-Kyu Kim; Chul-Hee Kim; Kwan-Ho Ko; Seong-Wook Park; Joong-Yeol Park; Ki-Up Lee
Journal:  Korean J Intern Med       Date:  2010-06-01       Impact factor: 3.165

8.  Short-term repeatability of electrocardiographic P wave indices and PR interval.

Authors:  Michelle L Snyder; Elsayed Z Soliman; Eric A Whitsel; Kapuaola S Gellert; Gerardo Heiss
Journal:  J Electrocardiol       Date:  2013-11-25       Impact factor: 1.438

9.  Heart rate variability, ambient particulate matter air pollution, and glucose homeostasis: the environmental epidemiology of arrhythmogenesis in the women's health initiative.

Authors:  Eric A Whitsel; P Miguel Quibrera; Sharon L Christ; Duanping Liao; Ronald J Prineas; Garnet L Anderson; Gerardo Heiss
Journal:  Am J Epidemiol       Date:  2009-02-10       Impact factor: 4.897

10.  Short-term repeatability of electrocardiographic criteria of left ventricular hypertrophy.

Authors:  Michelle L Meyer; Elsayed Z Soliman; Dominique Drager; Gerardo Heiss
Journal:  Ann Noninvasive Electrocardiol       Date:  2019-09-09       Impact factor: 1.468

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.