Literature DB >> 9532273

A silicone ventricular catheter coated with a combination of rifampin and trimethoprim for the prevention of catheter-related infections.

W Kohnen1, J Schäper, O Klein, B Tieke, B Jansen.   

Abstract

So-called antiinfective catheters which are generated by incorporation of antimicrobial substances into polymers appear to be effectful devices in the prevention of catheter related infections. Such devices mainly act by prevention of bacterial colonization of the catheter surface rather than by inhibition of adherence. In a preceding study, we developed a rifampin-containing silicone catheter for the prevention of ventricular shunt infection. In the present study, this work was continued with a combination of antimicrobials incorporated in silicone ventricular catheters to reduce the risk of rifampin resistance and to expand the antimicrobial spectrum. We found that the drug release kinetics could be greatly influenced by the incorporation conditions. It was possible to incorporate an optimal antibiotic combination of rifampin and trimethoprim into the polymer resulting in defined release rates and a defined total release. A catheter loaded with this combination showed an excellent reduction of the colonization with Staphylococcus aureus (99.97% reduction within 3 hours) under in-vitro conditions.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9532273     DOI: 10.1016/s0934-8840(98)80161-8

Source DB:  PubMed          Journal:  Zentralbl Bakteriol        ISSN: 0934-8840


  5 in total

Review 1.  Infections associated with medical devices: pathogenesis, management and prophylaxis.

Authors:  Christof von Eiff; Bernd Jansen; Wolfgang Kohnen; Karsten Becker
Journal:  Drugs       Date:  2005       Impact factor: 9.546

2.  Comparison of shunt infection incidence in high-risk subgroups receiving antibiotic-impregnated versus standard shunts.

Authors:  Scott L Parker; Frank J Attenello; Daniel M Sciubba; Giannina L Garces-Ambrossi; Edward Ahn; Jon Weingart; Benjamin Carson; George I Jallo
Journal:  Childs Nerv Syst       Date:  2008-11-05       Impact factor: 1.475

3.  Initial experience with antibiotic-impregnated silicone catheters for shunting of cerebrospinal fluid in children.

Authors:  Henry E Aryan; Hal S Meltzer; Min S Park; Rebecca L Bennett; Rahul Jandial; Michael L Levy
Journal:  Childs Nerv Syst       Date:  2004-10-12       Impact factor: 1.475

4.  Prolonged exposure to antibiotic-impregnated shunt catheters does not increase incidence of late shunt infections.

Authors:  Daniel M Sciubba; Matthew J McGirt; Graeme F Woodworth; Benjamin Carson; George I Jallo
Journal:  Childs Nerv Syst       Date:  2007-03-27       Impact factor: 1.532

5.  Lack of efficacy of antibiotic-impregnated shunt systems in preventing shunt infections in children.

Authors:  Peter Kan; John Kestle
Journal:  Childs Nerv Syst       Date:  2007-02-07       Impact factor: 1.532