Literature DB >> 9530036

Variability in the detection of enlarged mediastinal lymph nodes in staging lung cancer: a comparison of contrast-enhanced and unenhanced CT.

P N Cascade1, B H Gross, E A Kazerooni, L E Quint, I R Francis, M Strawderman, M Korobkin.   

Abstract

OBJECTIVE: Because CT protocols for staging lung cancer vary and little information exists regarding the diagnostic importance of using i.v. contrast material, our intent was to evaluate intra- and interobserver agreement in the detection of enlarged mediastinal lymph nodes, comparing i.v. contrast-enhanced and unenhanced CT. SUBJECTS AND METHODS: Fifty patients with known or suspected bronchogenic carcinoma underwent unenhanced thoracic CT followed by contrast-enhanced CT. Three observers noted enlarged lymph nodes (> 10 mm in the short axis) and assigned the enlarged nodes to American Thoracic Society nodal station designations. Enlarged lymph nodes were grouped two ways: by assigning the exact number of enlarged lymph nodes found (zero, one, two, three, four or more), and by assigning whether at least one, or no, enlarged mediastinal lymph nodes were found at a station ("one or none"). Agreement levels were determined for inter- and intraobserver interpretations using weighted kappa statistics and the McNemar test.
RESULTS: The number of enlarged lymph nodes with enhanced CT was 11% higher than on unenhanced studies (418 versus 377; p = .044). Numbers of enlarged lymph nodes were different for five stations; however, the numbers were small except for the right upper paratracheal station (2R) (contrast-enhanced, 68 enlarged lymph nodes; unenhanced, 44 enlarged lymph nodes; p = .014). With regard to all stations together, intraobserver agreement between contrast-enhanced and unenhanced studies was almost perfect (kappa range, .85-.94), and no difference was found for any observer in the proportion of patients with at least one enlarged lymph node. Interobserver agreement was substantial or almost perfect for the total number of enlarged lymph nodes. For specific stations, the lowest kappa value was .48 at 2R. One observer reported more patients with at least one enlarged lymph node with contrast enhancement at station 2R (p = .031). Greater agreement existed between two observers at station 2R with contrast enhancement versus no enhancement (kappa = .85 versus .48; p = .02). Conclusions matched, and calculations of estimated kappa values gave similar results for determination of the specific number of enlarged lymph nodes at a station and the "one or none" category.
CONCLUSION: We found high agreement for intra- and interobserver interpretations for contrast-enhanced and unenhanced CT, although contrast-enhanced CT revealed more enlarged lymph nodes, especially at station 2R.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9530036     DOI: 10.2214/ajr.170.4.9530036

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  8 in total

1.  Interobserver variability in the detection of mediastinal and hilar lymph nodes on CT in children with suspected pulmonary tuberculosis.

Authors:  Savvas Andronikou; Barbara Brauer; Jackie Galpin; Steven Brachmeyer; Susan Lucas; Elaine Joseph; George Dutoit; George Swingler
Journal:  Pediatr Radiol       Date:  2005-01-05

2.  Interobserver variability of clinical target volume delineation in supra-diaphragmatic Hodgkin's disease: a multi-institutional experience.

Authors:  Domenico Genovesi; Giampiero Ausili Cèfaro; Annamaria Vinciguerra; Antonietta Augurio; Monica Di Tommaso; Rita Marchese; Umberto Ricardi; Andrea Riccardo Filippi; Theodore Girinsky; Katiuscia Di Biagio; Maurizio Belfiglio; Enza Barbieri; Vincenzo Valentini
Journal:  Strahlenther Onkol       Date:  2011-05-16       Impact factor: 3.621

3.  Dosimetric study of Hounsfield number correction effect in areas influenced by contrast product in lungs case.

Authors:  Yassine Oulhouq; Dikra Bakari; Deae-Eddine Krim; Mustapha Zerfaoui; Abdeslem Rrhioua; Soufiane Berhili; Loubna Mezouar
Journal:  Rep Pract Oncol Radiother       Date:  2021-08-12

4.  Observer variation in FDG PET-CT for staging of non-small-cell lung carcinoma.

Authors:  Michael S Hofman; Nigel C Smeeton; Sheila C Rankin; Tom Nunan; Michael J O'Doherty
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-10-01       Impact factor: 9.236

5.  Data analysis: evaluation of nanoscale contrast agent enhanced CT scan to differentiate between benign and malignant lung cancer in mouse model.

Authors:  Robert C Bell; Deevakar Rogith; Craig W Johnson; Cristian T Badea; Khannan K Athreya; Gabriela Espinosa; Darin Clark; A Paiman Ghafoori; Yifan Li; David G Kirsch; Ananth Annapragada; Ketankumar Ghaghada
Journal:  AMIA Annu Symp Proc       Date:  2012-11-03

6.  A superficial hyperechoic band in human articular cartilage on ultrasonography with histological correlation: preliminary observations.

Authors:  Tae Sun Han; Kyu-Sung Kwack; Sunghoon Park; Byoung-Hyun Min; Seung-Hyun Yoon; Hyun Young Lee; Kyi Beom Lee
Journal:  Ultrasonography       Date:  2014-12-28

7.  High-resolution computed tomography findings of pulmonary tuberculosis in lung transplant recipients.

Authors:  Irai Luis Giacomelli; Roberto Schuhmacher Neto; Carlos Schuller Nin; Priscilla de Souza Cassano; Marisa Pereira; José da Silva Moreira; Douglas Zaione Nascimento; Bruno Hochhegger
Journal:  J Bras Pneumol       Date:  2017 Jul-Aug       Impact factor: 2.624

8.  The influence of contrast enhancement and experience of observers on the assessment of mediastinal lymph nodes in sarcoidosis patients.

Authors:  Magdalena Sobocinska; Marcin Białecki; Bartosz Sobocinski; Ida Martynowska; Jakub Ciescinski
Journal:  Pol J Radiol       Date:  2022-07-15
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.