Literature DB >> 9527585

[Ophthalmoscopic assessment of the size of the optic nerve papilla].

K I Papastathopoulos1, J B Jonas.   

Abstract

PURPOSE: To examine whether the optic disc size can be measured with common ophthalmoscopic lenses. PATIENTS AND METHODS: The horizontal and vertical disc diameters in 125 eyes of 65 patients were measured ophthalmoscopically using a commercial slit lamp with adjustable length of the beam and a Volk 60 diopters lens or a Volk Superfield lens. The refractive error of the subjects ranged between -7.25 D and +3.25 D (mean +/- S.D.: -0.34 +/- 1.77). Based on these measurements we calculated the optic disc area by applying a modified formula for an ellipse, where area = horizontal diameter x vertical diameter x pi/4. Additionally, we measured planimetrically the horizontal and vertical diameters of the optic disc on color stereo disc photographs after correcting the ocular and camera magnification according to Littmann's method.
RESULTS: The values of the horizontal and vertical disc diameters evaluated on the photographs were by factors of 1.0 and 1.5 larger than those values measured with the Volk 60 D lens, and the Volk Superfield lens, respectively. Taking into account these constant linear correction factors, the optic disc diameters as measured by the Volk 60 D lens and the Volk Superfield lens varied by 0.11 +/- 0.09 mm (5.9 +/- 5.1%), and 0.11 +/- 0.09 mm (5.9 +/- 4.9%), respectively, from the values measured on the photographs. The error for the ophthalmoscopic measurement of the disc diameters decreased slightly with increasing disc size. With highly myopic eyes excluded, it was independent of the refractive error.
CONCLUSION: For clinical purposes, the optic disc and other structures of the posterior fundus can be determined by ophthalmoscopy using a slit lamp and commonly used ophthalmoscopical lenses.

Entities:  

Mesh:

Year:  1997        PMID: 9527585     DOI: 10.1055/s-2008-1035137

Source DB:  PubMed          Journal:  Klin Monbl Augenheilkd        ISSN: 0023-2165            Impact factor:   0.700


  3 in total

1.  Evaluation and definition of physiologic macro cups with confocal optic nerve analysis (HRT).

Authors:  E Arenas-Archila; F Caycedo-Yunis; M R Rodríguez
Journal:  Int Ophthalmol       Date:  2001       Impact factor: 2.031

2.  Retinal vascular diameter in young subjects with a vasospastic propensity.

Authors:  Fabrizio Branca; Selim Orgül; Claudia Zawinka; Graziella Reinhard; Josef Flammer
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-08-23       Impact factor: 3.117

3.  Magnification-corrected indirect biomicroscopy of the optic nerve head.

Authors:  Siamak Ansari-Shahrezaei; Michael Stur
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2004-09-29       Impact factor: 3.117

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.