Literature DB >> 9520814

High-output cardiac failure secondary to a brachiocephalic arteriovenous hemodialysis fistula: two cases.

P R Young1, M S Rohr, W F Marterre.   

Abstract

The use of native arteriovenous fistulas for hemodialysis access is important to the success of this form of treatment for patients with end-stage renal disease. Native fistulas have been shown to provide improved longevity and to have lower complication rates when compared to prosthetic graft fistulas. High-output cardiac failure related to hemodialysis fistulas is an uncommon complication of their usage. Two renal transplant patients who did develop this complication from large well-developed brachiocephalic arteriovenous hemodialysis fistulas are presented. Both patients underwent successful transplantation and have required fistula ligation, with subsequent resolution of their cardiac failure. Native fistulas remain the best choice for hemodialysis access, but the clinician should remain aware of the possible untoward hemodynamic effects of these fistulas.

Entities:  

Mesh:

Year:  1998        PMID: 9520814

Source DB:  PubMed          Journal:  Am Surg        ISSN: 0003-1348            Impact factor:   0.688


  9 in total

1.  High-flow arteriovenous fistula and heart failure: could the indexation of blood flow rate and echocardiography have a role in the identification of patients at higher risk?

Authors:  Pasquale Zamboli; Sergio Lucà; Silvio Borrelli; Carlo Garofalo; Maria Elena Liberti; Mario Pacilio; Stefano Lucà; Giuseppe Palladino; Massimo Punzi
Journal:  J Nephrol       Date:  2018-01-22       Impact factor: 3.902

2.  Relation between access blood flow and mortality in chronic hemodialysis patients.

Authors:  Mohammed Al-Ghonaim; Braden J Manns; David J Hirsch; Zhiwei Gao; Marcello Tonelli
Journal:  Clin J Am Soc Nephrol       Date:  2008-01-30       Impact factor: 8.237

3.  The effect of a large proximal haemodialysis arterio-venous fistula on weaning off cardiopulmonary bypass: case report.

Authors:  Brian Nyawo; Amit Pawale; Leena Pardeshi; David Talbot; Jonathan Forty
Journal:  J Cardiothorac Surg       Date:  2008-07-09       Impact factor: 1.637

4.  Evaluation of arteriovenous fistulas made with the diamond-shaped anastomosis technique.

Authors:  Muhip Kanko; Cenk Sen; Sadan Yavuz; Cigdem Unal; Ahmet Aksoy; Turan Berkı
Journal:  Med Sci Monit       Date:  2012-09

5.  High-output cardiac failure secondary to a large arteriovenous fistula: a persistent threat to the dialysis and kidney transplant patient.

Authors:  Mohamad Khreiss; Fady F Haddad; Khaled M Musallam; Walid Medawar; Majida Daouk; Ismail Khalil
Journal:  NDT Plus       Date:  2009-01-16

6.  Improving the prognosis of patients with severely decreased glomerular filtration rate (CKD G4+): conclusions from a Kidney Disease: Improving Global Outcomes (KDIGO) Controversies Conference.

Authors:  Kai-Uwe Eckardt; Nisha Bansal; Josef Coresh; Marie Evans; Morgan E Grams; Charles A Herzog; Matthew T James; Hiddo J L Heerspink; Carol A Pollock; Paul E Stevens; Manjula Kurella Tamura; Marcello A Tonelli; David C Wheeler; Wolfgang C Winkelmayer; Michael Cheung; Brenda R Hemmelgarn
Journal:  Kidney Int       Date:  2018-04-12       Impact factor: 10.612

7.  The impact of haemodialysis arteriovenous fistula on haemodynamic parameters of the cardiovascular system.

Authors:  Carlo Basile; Luigi Vernaglione; Francesco Casucci; Pasquale Libutti; Piero Lisi; Luigi Rossi; Valentina Vigo; Carlo Lomonte
Journal:  Clin Kidney J       Date:  2016-07-15

8.  Endovascular Embolization in Problematic Hemodialysis Arteriovenous Fistulas: A Nonsurgical Technique.

Authors:  Raghunandan Prasad; Amrin Israrahmed; Rajanikant R Yadav; Somesh Singh; Manas Ranjan Behra; Ravi Shankar Khuswaha; Narayan Prasad; Hira Lal
Journal:  Indian J Nephrol       Date:  2020-11-07

9.  High-output cardiac failure secondary to high-output arteriovenous fistula: investigations, management and definitive treatment.

Authors:  James Leon Hartley; Asheesh Sharma; Lamis Taha; Thomas Hestletine
Journal:  BMJ Case Rep       Date:  2020-02-28
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.