Electrosynthesized non-conducting polymers as permselective membranes in amperometric enzyme electrodes: a glucose biosensor based on a co-crosslinked glucose oxidase/overoxidized polypyrrole bilayer.

A Guerrieri1, G E De Benedetto, F Palmisano, P G Zambonin.   

Abstract

A glucose amperometric biosensor based on glucose oxidase immobilized on an overoxidized polypyrrole (PPyox) platinum modified electrode, by glutaraldehyde co-crosslinking with bovine serum albumine, is described. The advantages of covalent immobilization techniques (e.g. high loading and long-term stability of the enzyme) are coupled with the excellent interferent rejection of electrosynthesized non-conducting polymers. The sensor showed an apparent Michaelis-Menten constant of 16 +/- 0.8 mM, a maximum current density of 490 microA/cm2 and a shelf lifetime of at least 3 months. Ascorbate, urate, cysteine and acetaminophen at their maximum physiological concentrations produced a glucose bias in the low micromolar range. Flow-injection response was linear up to 20 mM glucose with typical sensitivity of 84.0 +/- 1.5 nA/mM. The sensor was tested for glucose determination of untreated serum samples from both normal and diabetic subjects; results of amperometric assay compared well with those obtained by a standard enzymatic-colorimetric method.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9519453     DOI: 10.1016/s0956-5663(97)00064-x

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

1.  Optical sensor for the determination of glucose based on KIO4 chemiluminescence detection.

Authors:  Ming Li; Sang Hak Lee; Zun Ung Bae; Kwang Pill Lee; Yu Chul Park; Mu Sang Lee
Journal:  J Fluoresc       Date:  2004-09       Impact factor: 2.217

2.  Galvanostatic entrapment of penicillinase into polytyramine films and its utilization for the potentiometric determination of penicillin.

Authors:  Fatma Ismail; Samuel B Adeloju
Journal:  Sensors (Basel)       Date:  2010-03-29       Impact factor: 3.576

3.  Robust Functionalization of Large Microelectrode Arrays by Using Pulsed Potentiostatic Deposition.

Authors:  Joerg Rothe; Olivier Frey; Rajtarun Madangopal; Jenna Rickus; Andreas Hierlemann
Journal:  Sensors (Basel)       Date:  2016-12-23       Impact factor: 3.576

4.  A Crosstalk- and Interferent-Free Dual Electrode Amperometric Biosensor for the Simultaneous Determination of Choline and Phosphocholine.

Authors:  Rosanna Ciriello; Antonio Guerrieri
Journal:  Sensors (Basel)       Date:  2021-05-19       Impact factor: 3.576

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.