Literature DB >> 9516874

Impaired human coronary artery distensibility by atherosclerotic lesions: a mechanical and histological investigation.

O Frøbert1, J Schiønning, H Gregersen, U Baandrup, J A Petersen, J P Bagger.   

Abstract

The objective of this study was to evaluate the relationship between human coronary artery distensibility and vessel wall morphology assessed by histomorphometry. Coronary artery pressure-cross-sectional area relations and distensibility were studied in excised autopsy hearts by means of a balloon-based impedance planimetric technique 2 cm from the aortic orifice of the arteries. Later the hearts were perfusion fixed at 100 mm Hg and cross-sectioned 17, 20 and 23 mm distal to the aortic orifice. The areas of lumen, intima and media were measured. Nineteen left anterior descending coronary arteries (LAD) and 15 right coronary arteries (RCA) from 25 hearts (12 women and 13 men) were investigated. The age of the subjects was 48-97 years (mean 73.8 years). Non-linear relations were found between balloon pressure and coronary cross-sectional area (according with the function y = a + bx0.5) and between balloon pressure and coronary distensibility, but there were no differences in these relations between the LAD and RCA. Subjects' age was positively correlated with wall thickness (r = 0.44, P < 0.05), intima area (r = 0.46, P < 0.01) and media area (r = 0.44, P < 0.05) of the coronary arteries. Additionally, the distensibility at low pressures was inversely correlated with arterial wall thickness (r = -0.37, P < 0.05). When focusing only on arteries with concentric atherosclerotic lesions, distensibility at low pressures was inversely correlated with arterial wall thickness (r = -0.57, P = 0.01) and intima area (r = -0.53, P < 0.05). Arteries with concentric lesions were less distensible at low pressures compared with arteries having eccentric lesions (5.4 +/- 0.8.10(-2) vs. 3.6 +/- 0.7.10(-2) kPa-1, P < 0.05) but this difference was absent at higher pressures. No difference in coronary artery distensibility was found between men and women. Age and distensibility were not correlated. These findings may have in vivo implications for complications to angioplasty procedures such as recoil and restenosis.

Entities:  

Mesh:

Year:  1997        PMID: 9516874      PMCID: PMC2694552          DOI: 10.1046/j.1365-2613.1997.470374.x

Source DB:  PubMed          Journal:  Int J Exp Pathol        ISSN: 0959-9673            Impact factor:   1.925


  4 in total

1.  Expert Opinion: Optimising Stent Deployment in Contemporary Practice: The Role of Intracoronary Imaging and Non-compliant Balloons.

Authors:  Ashok Seth; Sajal Gupta; Vivudh Pratap Singh; Vijay Kumar
Journal:  Interv Cardiol       Date:  2017-09

2.  Coronary artery distensibility assessed by 3.0 Tesla coronary magnetic resonance imaging in subjects with and without coronary artery disease.

Authors:  Sebastian Kelle; Allison G Hays; Glenn A Hirsch; Gary Gerstenblith; Julie M Miller; Angela M Steinberg; Michael Schär; John H Texter; Ernst Wellnhofer; Robert G Weiss; Matthias Stuber
Journal:  Am J Cardiol       Date:  2011-05-31       Impact factor: 2.778

3.  Measurement of interstitial lactate during hypoxia-induced dilatation in isolated pressurised porcine coronary arteries.

Authors:  Ole Frøbert; Erich O Mikkelsen; Jens P Bagger; Claus H Gravholt
Journal:  J Physiol       Date:  2002-02-15       Impact factor: 5.182

4.  Effect of stent inflation pressure and post-dilatation on the outcome of coronary artery intervention. A report of more than 90,000 stent implantations.

Authors:  Ole Fröbert; Giovanna Sarno; Stefan K James; Nawsad Saleh; Bo Lagerqvist
Journal:  PLoS One       Date:  2013-02-13       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.