Literature DB >> 9516090

Effect of smaller droplet size of dornase alfa on lung function in mild cystic fibrosis. Dornase Alfa Nebulizer Group.

D E Geller1, H Eigen, S B Fiel, A Clark, A P Lamarre, C A Johnson, M W Konstan.   

Abstract

Aerosolized recombinant human DNase (dornase alfa) reduces mucus viscoelasticity in vitro and improves pulmonary function in patients with cystic fibrosis (CF). We postulated that if dornase alfa could be delivered more peripherally to small airways in the lung in the form of smaller aerosol droplets in patients with early airway obstruction, the increase in pulmonary function from baseline might be improved. CF patients (n = 749) with mild lung disease (baseline forced vital capacity > or = 70% predicted) were randomly assigned to receive dornase alfa 2.5 mg daily for 2 weeks by one of two nebulizer systems: 1) the Medic-Aid Durable SideStream nebulizer powered by the MobilAire Compressor (SS/MA) producing a droplet size with a mass median aerodynamic diameter (MMAD) of 2.1 microm; or 2) the Hudson T Up-draft nebulizer with a DeVilbiss Pulmo-Aide compressor (HT/PA) with an MMAD of 4.9 microm. Spirometry was performed at baseline and following 14 days of treatment. Dornase alfa delivered by both nebulizer systems produced small but statistically significant improvements in pulmonary function compared with baseline. There was a trend (P = 0.06) toward greater improvement in forced expiratory flow in 1 s in the SS/MA group (4.3%) compared with the HT/PA group (2.5%). These results indicate that the short-term spirometric response to dornase alfa is influenced in part by the physical characteristics of the aerosol in patients with mild lung disease. We speculate that this may be true for other therapeutic aerosols, and it appears that localization of disease in the lung plays a role in the response to inhaled agents.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9516090     DOI: 10.1002/(sici)1099-0496(199802)25:2<83::aid-ppul2>3.0.co;2-o

Source DB:  PubMed          Journal:  Pediatr Pulmonol        ISSN: 1099-0496


  2 in total

Review 1.  In vitro and in vivo aspects of cascade impactor tests and inhaler performance: a review.

Authors:  Jolyon Mitchell; Steve Newman; Hak-Kim Chan
Journal:  AAPS PharmSciTech       Date:  2007-12-21       Impact factor: 3.246

2.  Evaluation of the Target Inhalation Mode (TIM) breathing maneuver in simulated nebulizer therapy in patients with cystic fibrosis.

Authors:  John Denyer; Ivan Prince; Emma Dixon; Penny Agent; Jennifer Pryor; Margaret Hodson
Journal:  J Aerosol Med Pulm Drug Deliv       Date:  2010-04       Impact factor: 2.849

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.