Literature DB >> 9514451

Efficacy and safety of a hemostatic puncture closure device with early ambulation after coronary angiography. Angio-Seal Investigators.

S R Ward1, P Casale, R Raymond, W G Kussmaul, C Simpfendorfer.   

Abstract

A collagen hemostatic puncture closure device has been developed as an alternative to traditional manual pressure techniques for achieving effective femoral arterial hemostasis after coronary angiography. The purpose of the current study was to determine if patients receiving this device can ambulate safely at 1 hour compared with patients receiving traditional manual pressure and bed rest after sheath removal for diagnostic cardiac catheterization. Patients (n = 304) were randomized to either the device group (n = 202) with ambulation at 1 hour after sheath removal or to the manual pressure control group (n = 102) with ambulation at 4 to 6 hours after sheath removal. The device group achieved earlier time to hemostasis (0.9 +/- 3 vs 17.0 +/- 8 minutes, p = 0.0001) and faster time to outpatient discharge (5.0 +/- 4 vs 7.7 +/- 4 hours, p = 0.0001) compared with the control group. There were bleeding or vascular complications in 19 patients (9%) in the device group and in 6 patients (6%) in the manual pressure group (p = 0.397). In patients undergoing diagnostic coronary angiography, this device, compared with traditional techniques for achieving hemostasis after sheath removal, allows for faster time to effective hemostasis with resultant earlier discharge from the hospital.

Entities:  

Mesh:

Year:  1998        PMID: 9514451     DOI: 10.1016/s0002-9149(97)00970-3

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  12 in total

1.  [Hemostatic closure of arterial puncture site using Angio-Seal after diagnostic heart catheterization or coronary intervention].

Authors:  H Eggebrecht; M Haude; D Baumgart; O Oldenburg; J Herrmann; C Bruch; P Hunold; C Neurohr; C von Birgelen; D Welge; M A Katz; R Erbel
Journal:  Herz       Date:  1999-12       Impact factor: 1.443

2.  Z2D3 imaging: fringe or frontier?

Authors:  H W Strauss
Journal:  J Nucl Cardiol       Date:  1998 Nov-Dec       Impact factor: 5.952

3.  Usefulness of a Nonsuture Closure Device in Patients Undergoing Diagnostic Coronary and Peripheral Angiography.

Authors:  John T Owens; Shaun Bhatty; Robert J Donovan; Andrea Tordini; Peter Danyi; Kalpesh Patel; Jacob A Wegelin; Ion S Jovin
Journal:  Int J Angiol       Date:  2017-10-04

4.  Access-site complications after rescue percutaneous coronary intervention during thrombolysis for acute myocardial infarction.

Authors:  A Germing; M Lindstaedt; S Ulrich; W Bojara; T Lawo; A Mügge; P Grewe
Journal:  Z Kardiol       Date:  2005-01

5.  Large femoral aneurysm as a late complication after vessel closure device application.

Authors:  Alfried Germing; Peter Grewe; Andreas Mügge; Michael Lindstaedt
Journal:  Clin Res Cardiol       Date:  2006-04-03       Impact factor: 5.460

6.  The frequency of vascular complications associated with the use of vascular closure devices varies by indication for cardiac catheterization.

Authors:  Emilia Stegemann; Rainer Hoffmann; Steven Marso; Berthold Stegemann; Nikolaus Marx; Thomas Lauer
Journal:  Clin Res Cardiol       Date:  2011-04-11       Impact factor: 5.460

7.  The modified interventional method of antegrade common femoral artery access closure using the Angio-Seal device: modified Angio-Seal haemostasis technique: Modified Angio-Seal haemostasis technique.

Authors:  Yusuke Watanabe; Koji Hozawa; Sunao Nakamura
Journal:  AsiaIntervention       Date:  2022-03-15

8.  Short-Term Safety and Efficacy of Femoral Vascular Closure after Percutaneous Coronary Intervention with Combination of the Boomerang(TM) Device and Intravenous Protamine Sulfate.

Authors:  Ching-Pei Chen; Huang-Kai Huang; Chien-Hsun Hsia; Yung-Ming Chang; Lee-Shin Lin; Cheng-Liang Lee
Journal:  Acta Cardiol Sin       Date:  2013-11       Impact factor: 2.672

9.  Vascular closure device failure: frequency and implications: a propensity-matched analysis.

Authors:  Sripal Bangalore; Nipun Arora; Frederic S Resnic
Journal:  Circ Cardiovasc Interv       Date:  2009-10-27       Impact factor: 6.546

Review 10.  Network Meta-analysis of Randomized Trials on the Safety of Vascular Closure Devices for Femoral Arterial Puncture Site Haemostasis.

Authors:  Jun Jiang; Junjie Zou; Hao Ma; Yuanyong Jiao; Hongyu Yang; Xiwei Zhang; Yi Miao
Journal:  Sci Rep       Date:  2015-09-08       Impact factor: 4.379

View more