Reducing the influence of the partial volume effect on SPECT activity quantitation with 3D modelling of spatial resolution in iterative reconstruction.

P H Pretorius1, M A King, T S Pan, D J de Vries, S J Glick, C L Byrne.   

Abstract

Quantitative parameters such as the maximum and total counts in a volume are influenced by the partial volume effect. The magnitude of this effect varies with the non-stationary and anisotropic spatial resolution in SPECT slices. The objective of this investigation was to determine whether iterative reconstruction which includes modelling of the three-dimensional (3D) spatial resolution of SPECT imaging can reduce the impact of the partial volume effect on the quantitation of activity compared with filtered backprojection (FBP) techniques which include low-pass, and linear restoration filtering using the frequency distance relationship (FDR). The iterative reconstruction algorithms investigated were maximum-likelihood expectation-maximization (MLEM), MLEM with ordered subset acceleration (ML-OS), and MLEM with acceleration by the rescaled-block-iterative technique (ML-RBI). The SIMIND Monte Carlo code was used to simulate small hot spherical objects in an elliptical cylinder with and without uniform background activity as imaged by a low-energy ultra-high-resolution (LEUHR) collimator. Centre count ratios (CCRs) and total count ratios (TCRs) were determined as the observed counts over true counts. CCRs were unstable while TCRs had a bias of approximately 10% for all iterative techniques. The variance in the TCRs for ML-OS and ML-RBI was clearly elevated over that of MLEM, with ML-RBI having the smaller elevation. TCRs obtained with FDR-Wiener filtering had a larger bias (approximately 30%) than any of the iterative reconstruction methods but near stationarity is also reached. Butterworth filtered results varied by 9.7% from the centre to the edge. The addition of background has an influence on the convergence rate and noise properties of iterative techniques.

Entities:  

Mesh:

Year:  1998        PMID: 9509535     DOI: 10.1088/0031-9155/43/2/014

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  14 in total

1.  The effect of adaptive iterative dose reduction on image quality in 320-detector row CT coronary angiography.

Authors:  F Tatsugami; M Matsuki; G Nakai; Y Inada; S Kanazawa; Y Takeda; H Morita; H Takada; S Yoshikawa; K Fukumura; Y Narumi
Journal:  Br J Radiol       Date:  2012-01-17       Impact factor: 3.039

2.  Image quality of multiplanar reconstruction of pulmonary CT scans using adaptive statistical iterative reconstruction.

Authors:  O Honda; M Yanagawa; A Inoue; A Kikuyama; S Yoshida; H Sumikawa; K Tobino; M Koyama; N Tomiyama
Journal:  Br J Radiol       Date:  2010-11-16       Impact factor: 3.039

3.  Iterative reconstruction or filtered backprojection for semi-quantitative assessment of dopamine D₂ receptor SPECT studies?

Authors:  Walter Koch; Christine Suessmair; Klaus Tatsch; Gabriele Pöpperl
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-02-02       Impact factor: 9.236

4.  Diminishing the impact of the partial volume effect in cardiac SPECT perfusion imaging.

Authors:  P Hendrik Pretorius; Michael A King
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

Review 5.  Quantitative assessment of regional myocardial blood flow with thallium-201 and SPECT.

Authors:  H Iida; S Eberl
Journal:  J Nucl Cardiol       Date:  1998 May-Jun       Impact factor: 5.952

Review 6.  SPECT/CT: an update on technological developments and clinical applications.

Authors:  Michael Ljungberg; P Hendrik Pretorius
Journal:  Br J Radiol       Date:  2017-01-16       Impact factor: 3.039

Review 7.  Absolute quantification in SPECT.

Authors:  Philipp Ritt; Hans Vija; Joachim Hornegger; Torsten Kuwert
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-04-12       Impact factor: 9.236

8.  Collimator optimization and collimator-detector response compensation in myocardial perfusion SPECT using the ideal observer with and without model mismatch and an anthropomorphic model observer.

Authors:  Michael Ghaly; Jonathan M Links; Eric C Frey
Journal:  Phys Med Biol       Date:  2016-02-19       Impact factor: 3.609

9.  Absolute quantitation of myocardial blood flow with (201)Tl and dynamic SPECT in canine: optimisation and validation of kinetic modelling.

Authors:  Hidehiro Iida; Stefan Eberl; Kyeong-Min Kim; Yoshikazu Tamura; Yukihiko Ono; Mayumi Nakazawa; Antti Sohlberg; Tsutomu Zeniya; Takuya Hayashi; Hiroshi Watabe
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-01-15       Impact factor: 9.236

Review 10.  Oxytocin and vasopressin systems in genetic syndromes and neurodevelopmental disorders.

Authors:  S M Francis; A Sagar; T Levin-Decanini; W Liu; C S Carter; S Jacob
Journal:  Brain Res       Date:  2014-01-22       Impact factor: 3.252

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.