Literature DB >> 9508272

MRI visualization of small structures using improved surface coils.

M Rivera1, J J Vaquero, A Santos, J Ruiz-Cabello, F del Pozo.   

Abstract

In this paper we present the spatial resolution enhancement and noise reduction level achieved with an optimized inductively coupled surface coil specifically designed for our experiments. The technique of designing and implementing customized coils for magnetic resonance imaging of very small structures is described. We have designed a low cost prototype of an inductively coupled circular surface coil, tuned for 1H magnetic resonance imaging at 200 MHz. The coil is mounted on a customized teflon support. The inductive coupling used in this coil improves the signal-to-noise ratio by reducing various loss mechanisms (specially the dielectric losses). Test images have been acquired to determine the evolution of induced articular lesions in a rabbit animal model, as well as brain tumors in rats. The images show high spatial resolution, excellent B1 field homogeneity and no "hot spots". Comparing these images with those acquired with conventional coils, one finds better spatial resolution and signal-to-noise ratio, as well as larger field of view with less intense illumination artifact. The methodology can be used in any application that requires high quality imaging of small structures.

Entities:  

Mesh:

Year:  1998        PMID: 9508272     DOI: 10.1016/s0730-725x(97)00273-7

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  4 in total

1.  Volumetric analysis of mice lungs in a clinical magnetic resonance imaging scanner.

Authors:  Johannes T Heverhagen; Horst K Hahn; Michael Wegmann; Udo Herz; Chastity D Shaffer Whitaker; Volker Matschl; Heiko Alfke
Journal:  MAGMA       Date:  2004-10-05       Impact factor: 2.310

2.  Experimental MR imaging of the rabbit brain: How to perform it better.

Authors:  Nil Tokgoz; Memduh Kaymaz; A Yusuf Oner; Hakan Emmez
Journal:  AJNR Am J Neuroradiol       Date:  2006-04       Impact factor: 3.825

3.  MR-guided biopsies with a newly designed cordless coil in an open low-field system: initial findings.

Authors:  Stephan Zangos; Theodor Vetter; Frank Huebner; Montu Tuwari; Florian Mayer; Katrin Eichler; M-L Hansmann; A Wetter; C Herzog; Thomas J Vogl
Journal:  Eur Radiol       Date:  2005-12-13       Impact factor: 5.315

4.  The Pathophysiological Sequence of Glucocorticoid-Induced Osteonecrosis of the Femoral Head in Male Mice.

Authors:  Robert S Weinstein; Erin A Hogan; Michael J Borrelli; Serguei Liachenko; Charles A O'Brien; Stavros C Manolagas
Journal:  Endocrinology       Date:  2017-11-01       Impact factor: 4.736

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.