Literature DB >> 9505138

A critical analysis of stress shielding evaluation of hip prostheses.

L Cristofolini1.   

Abstract

In vitro evaluation of the load transfer of hip prostheses has been performed in recent years for the purpose of understanding the stress shielding phenomena. Over 200 papers were reviewed to determine if a standard exists to evaluate and compare the performance of hip stems. Surprisingly, it was found that little agreement exists in the testing protocol. This makes it very difficult to compare the results reported in different investigations. In several cases very incomplete data are reported about the testing conditions, thus making it impossible to compare the results. This article focuses on: (1) how the loading conditions should be chosen based on physiological loading in a way to give a reproducible setup; (2) how the femur should be constrained; (3) how to generate the same system of loads in the intact and the implanted femur; (4) how to define a reference system; (5) how the specimen type and sample size are chosen; (6) the advantages and limitations of the different strain measurement techniques; (7) how the testing parameters have been chosen in the literature; and (8) how the accuracy of the results has been reported in the literature.

Mesh:

Year:  1997        PMID: 9505138     DOI: 10.1615/critrevbiomedeng.v25.i4-5.30

Source DB:  PubMed          Journal:  Crit Rev Biomed Eng        ISSN: 0278-940X


  11 in total

1.  Femoral Iatrogenic Subtrochanteric Fatigue Fracture Risk is not Increased by Placing Drill Holes Below the Level of the Lesser Trochanter.

Authors:  Andrew G Tsai; Timothy J Ashworth; Randall Marcus; Ozan Akkus
Journal:  Iowa Orthop J       Date:  2017

2.  Fractures of the proximal femur: correlates of radiological evidence of osteoporosis.

Authors:  Luca Cristofolini
Journal:  Skeletal Radiol       Date:  2007-05-09       Impact factor: 2.128

3.  Differences in external and internal cortical strain with prosthesis in the femur.

Authors:  Olav Reikeras; Gudrun T Aarnes; Harald Steen; Per Ludvigsen; Geir Sagvolden
Journal:  Open Orthop J       Date:  2011-11-18

4.  Daily application of low magnitude mechanical stimulus inhibits the growth of MDA-MB-231 breast cancer cells in vitro.

Authors:  Melis Olcum; Engin Ozcivici
Journal:  Cancer Cell Int       Date:  2014-10-14       Impact factor: 5.722

5.  In vitro hip testing in the International Society of Biomechanics coordinate system.

Authors:  Richard J van Arkel; Jonathan R T Jeffers
Journal:  J Biomech       Date:  2016-10-29       Impact factor: 2.712

6.  Anatomic grooved stem mitigates strain shielding compared to established total hip arthroplasty stem designs in finite-element models.

Authors:  Mark Heyland; Sara Checa; Daniel Kendoff; Georg N Duda
Journal:  Sci Rep       Date:  2019-01-24       Impact factor: 4.379

Review 7.  Biomaterial-based strategies for maxillofacial tumour therapy and bone defect regeneration.

Authors:  Bowen Tan; Quan Tang; Yongjin Zhong; Yali Wei; Linfeng He; Yanting Wu; Jiabao Wu; Jinfeng Liao
Journal:  Int J Oral Sci       Date:  2021-03-16       Impact factor: 6.344

8.  Sensitivity of the stress field of the proximal femur predicted by CT-based FE analysis to modeling uncertainties.

Authors:  Sina Youssefian; Jarred A Bressner; Mikhail Osanov; James K Guest; Wojciech B Zbijewski; Adam S Levin
Journal:  J Orthop Res       Date:  2021-07-13       Impact factor: 3.102

9.  Variation in bone response to the placement of percutaneous osseointegrated endoprostheses: A 24-month follow-up in sheep.

Authors:  Sujee Jeyapalina; James Peter Beck; Alex Drew; Roy D Bloebaum; Kent N Bachus
Journal:  PLoS One       Date:  2019-10-25       Impact factor: 3.240

10.  Comparative analysis of the biomechanical behavior of two different design metaphyseal-fitting short stems using digital image correlation.

Authors:  I Tatani; P Megas; A Panagopoulos; I Diamantakos; Ph Nanopoulos; Sp Pantelakis
Journal:  Biomed Eng Online       Date:  2020-08-19       Impact factor: 2.819

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.