Cardiopulmonary interaction during partial liquid ventilation in surfactant-treated preterm lambs.

A Davidson1, J L Heckman, R M Donner, T F Miller, T H Shaffer, M R Wolfson.   

Abstract

UNLABELLED: Gas ventilation following instillation of perfluorochemical (PFC) liquid, partial liquid ventilation (PLV), improves gas exchange and pulmonary mechanics in neonatal animals and humans with severe respiratory distress. The effect of PLV on cardiac contractility, performance, pulmonary blood flow and ductal shunt has not been fully described. To this end, we evaluated these indices of cardiopulmonary function in eight conventionally gas ventilated, surfactant-treated premature lambs (125 days gestation) before and during PLV. Animals were instrumented with central venous and aortic lines. Serial evaluation of arterial blood chemistry/pressure, and pulmonary mechanics was performed; cardiac contractility, performance, pulmonary blood flow and ductal shunts were serially assessed by echocardiography. As compared to conventional gas ventilation, during PLV there was a significant decrease in left ventricular meridian (22.5+/-6.6 SE vs 8.1+/-1.4 SE g/cm2, P < 0.02) and circumferential wall stress (54.1+/-16.5 vs 24.4+/-3.8 SE g/cm2, P < 0.04) at end systole. The fall in wall stress at end systole was associated with a significant decrease in left ventricular internal diameter (1.2+/-0.05 SE vs 1.04+/-0.045 SE cm; P < 0.01). There were no significant changes in heart rate, systemic arterial and central venous pressures, systemic vascular resistance, left ventricular shortening and ejection fractions during PLV. The decrease in wall stress was associated with a significant decrease in mean airway pressures (15.9+/-1.1 SE vs 9.9+/-0.2 SE cmH2O; P < 0.05) and ostensibly a change in intrathoracic pressures during PLV. There were no significant differences in blood flows (pre vs during PLV; ml/min/kg): pulmonary (226+/-62 SE vs 293+/-65 SE), aortic (237+/-36 SE vs 204+/-21 SE), and left to right ductal (119+/-25 SE vs 105.5+/-26 SE) measured before and during PLV.
CONCLUSION: Cardiac output and pulmonary blood flow do not change significantly during PLV and therefore do not appear to contribute to improved gas exchange. This stable cardiac performance occurs at lower wall stress and thereby more advantageous energetic conditions.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9504789     DOI: 10.1007/s004310050786

Source DB:  PubMed          Journal:  Eur J Pediatr        ISSN: 0340-6199            Impact factor:   3.183


  2 in total

Review 1.  Administration of Drugs/Gene Products to the Respiratory System: A Historical Perspective of the Use of Inert Liquids.

Authors:  Deepthi Alapati; Thomas H Shaffer
Journal:  Front Physiol       Date:  2022-05-10       Impact factor: 4.755

2.  Changes in FiO2 affect PaO2 with minor alterations in cerebral concentration of oxygenated hemoglobin during liquid ventilation in healthy piglets.

Authors:  Wolfram Burkhardt; Hans Proquitté; Susann Krause; Roland R Wauer; Mario Rüdiger
Journal:  Intensive Care Med       Date:  2004-01-14       Impact factor: 17.440

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.