Literature DB >> 9504594

Utility of chest radiographs after guidewire exchanges of central venous catheters.

P Frassinelli1, M D Pasquale, M D Cipolle, M Rhodes.   

Abstract

OBJECTIVE: To determine whether chest radiographs are warranted after uncomplicated guidewire exchanges of central venous catheters in patients admitted to a Level I trauma intensive care unit.
DESIGN: Prospective study performed in two phases.
SETTING: Intensive care unit in a Level I trauma center. PATIENTS: Patients admitted to a Level I trauma center intensive care unit who required central venous catheter guidewire exchanges.
INTERVENTIONS: Criteria for uncomplicated guidewire exchanges were established and followed. A catheter exchange checklist was completed at each procedure, and a chest radiograph was performed after each guidewire exchange. The complications followed were catheter malposition, pneumothorax, hemothorax, and cardiac tamponade. Results were reviewed after 3 mos, and a second phase of the study was initiated in which chest radiographs were obtained selectively and were not performed for uncomplicated exchanges. If obtained, subsequent radiographs were reviewed, and patients were followed to discharge for complications.
MEASUREMENTS AND MAIN RESULTS: One hundred central venous catheter exchanges with postprocedure radiographs were evaluated in phase I. The only complication identified was one malpositioned catheter. In phase II, 110 patients were followed. Eighty-four patients did not have chest radiographs performed after guidewire exchange; 69 patients had subsequent radiographs documenting good placement of the catheter, and 15 patients did not have a radiograph before death (n = 2) or discharge from the hospital (n = 13). Sixteen patients had postprocedure radiographs performed. There were no malpositioned catheters or complications related to guidewire exchanges.
CONCLUSIONS: Chest radiographs are unwarranted after uncomplicated guidewire exchanges of central venous catheters in hemodynamically stable, monitored patients. Eliminating these radiographs will result in significant cost and time savings without adversely affecting patient outcome.

Entities:  

Mesh:

Year:  1998        PMID: 9504594     DOI: 10.1097/00003246-199803000-00040

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  4 in total

Review 1.  Diagnosis of pneumothorax in critically ill adults.

Authors:  J J Rankine; A N Thomas; D Fluechter
Journal:  Postgrad Med J       Date:  2000-07       Impact factor: 2.401

Review 2.  Routine chest x-rays in intensive care units: a systematic review and meta-analysis.

Authors:  Anusoumya Ganapathy; Neill K J Adhikari; Jamie Spiegelman; Damon C Scales
Journal:  Crit Care       Date:  2012-12-12       Impact factor: 9.097

3.  Chest radiograph in subclavian vein cannulation.

Authors:  Haider Abbas; Ajay Chowdhary; Jaishree Bogra
Journal:  Indian J Crit Care Med       Date:  2011-07

4.  Indian Society of Critical Care Medicine Position Statement for Central Venous Catheterization and Management 2020.

Authors:  Yash Javeri; Ganshyam Jagathkar; Subhal Dixit; Dhruva Chaudhary; Kapil Gangadhar Zirpe; Yatin Mehta; Deepak Govil; Rajesh C Mishra; Srinivas Samavedam; Rahul Anil Pandit; Raymond Dominic Savio; Anuj M Clerk; Shrikanth Srinivasan; Deven Juneja; Sumit Ray; Tapas Kumar Sahoo; Srinivas Jakkinaboina; Nandhakishore Jampala; Ravi Jain
Journal:  Indian J Crit Care Med       Date:  2020-01
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.