Literature DB >> 9500272

MRI monitoring of interstitial microwave-induced heating and thermal lesions in rabbit brain in vivo.

J A Moriarty1, J C Chen, C M Purcell, L C Ang, R S Hinks, R D Peters, R M Henkelman, D B Plewes, M J Bronskill, W Kucharczyk.   

Abstract

The purpose of this experiment was to use MRI to monitor microwave heating and thermal damage of brain tissue in vivo. Interstitial microwave antennas were implanted into the cerebral hemispheres of seven anesthetized rabbits. Variable power of 30 to 100 W was applied for periods of 5 to 15 minutes and tissue temperature was monitored continuously. MR images were obtained throughout the procedure at 20-second intervals, using a spoiled gradient-echo sequence, without significant artifact. Magnitude, phase, and complex difference images all demonstrated temperature-related signal changes during heating. The findings were better visualized on the phase and complex difference images. Phase difference image analysis revealed an approximately linear relationship between phase change and temperature. Post-treatment thermal lesions measured up to 2.0 cm in size on pathologic specimens and exhibited a zonal pattern on spin-echo MR images.

Entities:  

Mesh:

Year:  1998        PMID: 9500272     DOI: 10.1002/jmri.1880080125

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  6 in total

1.  MR monitoring of tumour thermal therapy.

Authors:  D Germain; P Chevallier; A Laurent; H Saint-Jalmes
Journal:  MAGMA       Date:  2001-08       Impact factor: 2.310

2.  Quantitative magnetic resonance temperature mapping for real-time monitoring of radiofrequency ablation of the liver: an ex vivo study.

Authors:  Olivier Seror; Matthieu Lepetit-Coiffé; Bruno Quesson; Hervé Trillaud; Chrit T W Moonen
Journal:  Eur Radiol       Date:  2006-04-11       Impact factor: 5.315

3.  Real time monitoring of radiofrequency ablation based on MR thermometry and thermal dose in the pig liver in vivo.

Authors:  Olivier Seror; Matthieu Lepetit-Coiffé; Brigitte Le Bail; Baudouin Denis de Senneville; Hervé Trillaud; Chrit Moonen; Bruno Quesson
Journal:  Eur Radiol       Date:  2007-09-26       Impact factor: 5.315

Review 4.  MR thermometry.

Authors:  Viola Rieke; Kim Butts Pauly
Journal:  J Magn Reson Imaging       Date:  2008-02       Impact factor: 4.813

5.  Experimental assessment of microwave ablation computational modeling with MR thermometry.

Authors:  Pegah Faridi; Paul Keselman; Hojjatollah Fallahi; Punit Prakash
Journal:  Med Phys       Date:  2020-07-16       Impact factor: 4.071

6.  Case studies in neuroscience: reversible signatures of edema following electric and piezoelectric craniotomy drilling in macaques.

Authors:  Rober Boshra; Manoj Eradath; Kacie Dougherty; Bichan Wu; Britney M Morea; Michael Harris; Mark A Pinsk; Sabine Kastner
Journal:  J Neurophysiol       Date:  2022-08-31       Impact factor: 2.974

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.