Literature DB >> 9500269

A method for simultaneous RF ablation and MRI.

Q Zhang1, Y C Chung, J S Lewin, J L Duerk.   

Abstract

Radiofrequency (RF) energy has many advantages in thermal tumor ablation protocols. With the recent development of open MRI systems, interventional MRI procedures, including thermal ablation, have become the focus of great research interest. However, the significant interference between RF generators and MR imagers has prevented simultaneous imaging and RF ablation and, until now, has limited the role of RF-based thermal therapy in interventional MRI. Here, a simple switching circuit designed with consideration of patient safety provides compatibility between open MRI systems and RF thermal lesion generators. The experimental results show that the switching circuit allows imaging during RF ablation and opens new opportunity for MR-guided thermal therapy.

Entities:  

Mesh:

Year:  1998        PMID: 9500269     DOI: 10.1002/jmri.1880080122

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  13 in total

1.  High-fidelity computer models for prospective treatment planning of radiofrequency ablation with in vitro experimental correlation.

Authors:  David Fuentes; Rex Cardan; R Jason Stafford; Joshua Yung; Gerald D Dodd; Yusheng Feng
Journal:  J Vasc Interv Radiol       Date:  2010-11       Impact factor: 3.464

2.  Morphological, contrast-enhanced and spin labeling perfusion imaging for monitoring of relapse after RF ablation of renal cell carcinomas.

Authors:  Andreas Boss; Petros Martirosian; Christina Schraml; Stephan Clasen; Michael Fenchel; Artistotelis Anastasiadis; Claus D Claussen; Philippe L Pereira; Fritz Schick
Journal:  Eur Radiol       Date:  2006-01-27       Impact factor: 5.315

3.  Numerical simulations of intra-voxel dephasing effects and signal voids in gradient echo MR imaging using different sub-grid sizes.

Authors:  Bernd M Müller-Bierl; Hansjörg Graf; Philippe L Pereira; Fritz Schick
Journal:  MAGMA       Date:  2006-05-09       Impact factor: 2.310

4.  Quantitative magnetic resonance temperature mapping for real-time monitoring of radiofrequency ablation of the liver: an ex vivo study.

Authors:  Olivier Seror; Matthieu Lepetit-Coiffé; Bruno Quesson; Hervé Trillaud; Chrit T W Moonen
Journal:  Eur Radiol       Date:  2006-04-11       Impact factor: 5.315

Review 5.  MR thermometry.

Authors:  Viola Rieke; Kim Butts Pauly
Journal:  J Magn Reson Imaging       Date:  2008-02       Impact factor: 4.813

6.  Radiofrequency ablation of small liver malignancies under magnetic resonance guidance: progress in targeting and preliminary observations with temperature monitoring.

Authors:  Sylvain Terraz; Alexandru Cernicanu; Matthieu Lepetit-Coiffé; Magalie Viallon; Rares Salomir; Gilles Mentha; Christoph D Becker
Journal:  Eur Radiol       Date:  2009-09-16       Impact factor: 5.315

7.  Magnetic Resonance Mediated Radiofrequency Ablation.

Authors:  Yik-Kiong Hue; Alexander R Guimaraes; Ouri Cohen; Erez Nevo; Abraham Roth; Jerome L Ackerman
Journal:  IEEE Trans Med Imaging       Date:  2017-09-18       Impact factor: 10.048

Review 8.  Image-guided thermal therapy of uterine fibroids.

Authors:  Shu-Huei Shen; Fiona Fennessy; Nathan McDannold; Ferenc Jolesz; Clare Tempany
Journal:  Semin Ultrasound CT MR       Date:  2009-04       Impact factor: 1.875

Review 9.  Magnetic Resonance Imaging-Guided Breast Interventions: Role in Biopsy Targeting and Lumpectomies.

Authors:  Eva C Gombos; Jayender Jagadeesan; Danielle M Richman; Daniel F Kacher
Journal:  Magn Reson Imaging Clin N Am       Date:  2015-07-08       Impact factor: 2.266

10.  Magnetocaloric materials as switchable high contrast ratio MRI labels.

Authors:  Mladen Barbic; Stephen J Dodd; H Douglas Morris; Neil Dilley; Barbara Marcheschi; Alan Huston; Tim D Harris; Alan P Koretsky
Journal:  Magn Reson Med       Date:  2018-11-25       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.