Literature DB >> 9499524

[In vivo measurement of 3-dimensional movement of the iliosacral joint].

H J Wilke1, K Fischer, B Jeanneret, L Claes, F Magerl.   

Abstract

The purpose of this study was to quantify in vivo the three-dimensional motion patterns of the sacroiliac joint during passive manipulations as the opinions about the extent of motion of this joint are varied. 12 sacroiliac joints of 6 patients with clinically and radiologically normal joints were investigated. All patients were treated with an external fixator for diagnostic purposes of low back pain unrelated of this study. The motion of the sacroiliac joint was measured continuously with a three-dimensional goniometric system, which was mounted at the end of Schanz screws implanted in S1 and the ilium. All measurements showed relatively small rotation angles around the three main axis to the body between the ilium and the sacrum (< 2 degrees) and very small translations between the screw entry points into the bones (< 1 mm). The maximum rotation angle in the sagittal plane was 1.3 degrees on the right joint and 1.6 degrees on the left joint for flexion plus extension. It is questionable whether this motion can be quantified during manual manipulation. Extension of the hip always produced the largest motion in the sacroiliac joint.

Entities:  

Mesh:

Year:  1997        PMID: 9499524     DOI: 10.1055/s-2008-1039744

Source DB:  PubMed          Journal:  Z Orthop Ihre Grenzgeb        ISSN: 0044-3220


  6 in total

1.  Three-dimensional movements of the sacroiliac joint: a systematic review of the literature and assessment of clinical utility.

Authors:  Adam Goode; Eric J Hegedus; Philip Sizer; Jean-Michel Brismee; Alison Linberg; Chad E Cook
Journal:  J Man Manip Ther       Date:  2008

2.  Minimally invasive sacroiliac joint fusion vs. conservative management for chronic sacroiliac joint pain.

Authors:  David W Polly
Journal:  J Spine Surg       Date:  2019-09

3.  Radiological Assessment of the Sacrofemoral Angle: A Novel Method to Measure the Range of Hip Joint Flexion.

Authors:  Xian-Zhao Wei; Xi-Ming Xu; Fei Wang; Ming Li; Zi-Min Wang
Journal:  Chin Med J (Engl)       Date:  2015-09-05       Impact factor: 2.628

4.  Comparative Analysis of Optoelectronic Accuracy in the Laboratory Setting Versus Clinical Operative Environment: A Systematic Review.

Authors:  Bryan W Cunningham; Daina M Brooks
Journal:  Global Spine J       Date:  2022-04

5.  Standard reference values of the upper body posture in healthy male adults aged between 51 and 60 years in Germany.

Authors:  Daniela Ohlendorf; Dominik Krüger; Wolfgang Christian; Hanns Ackermann; Fee Keil; Gerhard Oremek; Christian Maurer-Grubinger; David A Groneberg
Journal:  Sci Rep       Date:  2022-04-28       Impact factor: 4.996

6.  A finite element analysis of sacroiliac joint displacements and ligament strains in response to three manipulations.

Authors:  Zhun Xu; Yikai Li; Shaoqun Zhang; Liqing Liao; Kai Wu; Ziyu Feng; Dan Li
Journal:  BMC Musculoskelet Disord       Date:  2020-10-28       Impact factor: 2.362

  6 in total