C H Jensen1, M Hansen, J Brandt, H B Rasmussen, P B Jensen, B Teisner.
Abstract
This paper compares the results of procollagen type I N-terminal propeptide (PINP) quantification by radioimmunoassay (RIA) and enzyme linked immunosorbent assay (ELISA). PINP in serum from a patient with uremic hyperparathyroidism was measured in RIA and ELISA to 20 micrograms l-1 and 116 micrograms l-1 and the corresponding concentrations in dialysis fluid were 94.5 micrograms l-1 and 140 micrograms l-1, respectively. PINP antigen appears in two distinct peaks following size chromatography and the two peak fractions display immunological identity and identical M(r)'s (27 kDa: SDS-PAGE). Analysis of fractions from size separated amniotic fluid, serum and dialysis fluid demonstrated that the RIA failed to measure the low molecular weight form of PINP. However, the anti-PINP supplied with the RIA-kit and the anti-PINP applied in the ELISA reacted equally well with both molecular forms of PINP when analysed in a direct ELISA. It is concluded that the major difference in the ELISA and RIA results is due to assay efficacy with respect to the low molecular weight form of PINP.Entities:
Mesh:
Substances:
Year: 1998 PMID: 9498102 DOI: 10.1016/s0009-8981(97)00182-4
Source DB: PubMed Journal: Clin Chim Acta ISSN: 0009-8981 Impact factor: 3.786