Literature DB >> 9494336

[The results of questionnaire on quantitative assessment of 123I-metaiodobenzylguanidine myocardial scintigraphy in heart failure].

T Nishimura1, Y Sugishita, Y Sasaki.   

Abstract

This study was done by working group under the cooperation between Japanese Society of Nuclear Medicine and Japanese Circulation Society. We evaluated the usefulness of quantitative assessment of 123I-metaiodobenzylguanidine (MIBG) myocardial scintigraphy in heart failure by the results of questionnaire. Forty-nine (72.1%) of 68 selected institutions participated in this study. The incidence of MIBG myocardial scintigraphy used in heart failure was 41.1%. The imaging protocol was mostly done by both planar and SPECT at 15 min and 3.6 hr after intravenous injection of 111 MBq of MIBG. The quantitative assessment was mostly done by heart/mediastinum (H/M) ratio and washout rate analysis based on planar imaging. The mean normal value of H/M ratio were 2.34 +/- 0.36, and 2.49 +/- 0.40, at early and delayed images, respectively. The normal value of washout rate was 27.74 +/- 5.34%. On the other hand, those of H/M ratio in heart failure were 1.87 +/- 0.27, and 1.75 +/- 0.24, at early and delayed images, respectively. That of washout rate was 42.30 +/- 6.75%. These parameters were very useful for the evaluation of heart failure. In conclusion, MIBG myocardial scintigraphy was widely used for not only early detection and severity assessment, but also indication for therapy and prognosis evaluation in heart failure patients.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9494336

Source DB:  PubMed          Journal:  Kaku Igaku        ISSN: 0022-7854


  7 in total

1.  Role of MIBG myocardial scintigraphy in the assessment of heart failure: the need to establish evidence.

Authors:  Shohei Yamashina; Jun-ichi Yamazaki
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-03-17       Impact factor: 9.236

2.  Semi-automated algorithm for calculating heart-to-mediastinum ratio in cardiac Iodine-123 MIBG imaging.

Authors:  Koichi Okuda; Kenichi Nakajima; Tetsuo Hosoya; Takehiro Ishikawa; Takahiro Konishi; Kosuke Matsubara; Shinro Matsuo; Seigo Kinuya
Journal:  J Nucl Cardiol       Date:  2010-11-23       Impact factor: 5.952

3.  Standardization of the heart-to-mediastinum ratio of 123I-labelled-metaiodobenzylguanidine uptake using the dual energy window method: feasibility of correction with different camera-collimator combinations.

Authors:  Shinro Matsuo; Kenichi Nakajima; Koichi Okuda; Masaya Kawano; Takehiro Ishikawa; Tetsuo Hosoya; Junichi Taki; Seigo Kinuya
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-11-07       Impact factor: 9.236

Review 4.  Neuronal imaging using SPECT.

Authors:  Shohei Yamashina; Jun-ichi Yamazaki
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-06       Impact factor: 9.236

Review 5.  Imaging cardiac neuronal function and dysfunction.

Authors:  Takahiro Higuchi; Markus Schwaiger
Journal:  Curr Cardiol Rep       Date:  2006-03       Impact factor: 2.931

Review 6.  Neuronal imaging using SPECT.

Authors:  Shohei Yamashina; Jun-ichi Yamazaki
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-06       Impact factor: 10.057

Review 7.  I -123 metaiodobenzylguanidine imaging for predicting ventricular arrhythmia in heart failure patients.

Authors:  Weihua Zhou; Ji Chen
Journal:  J Biomed Res       Date:  2013-09-25
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.