S Wilhelm1, T Standl. 1. Abteilung für Anästhesiologie, Universitäts-Krankenhaus Eppendorf, Hamburg.
Abstract
UNLABELLED: In this prospective study we investigated the efficacy of microcatheter spinal anaesthesia in comparison with a combined spinal-epidural technique in trauma patients. METHODS: After institutional approval 60 patients undergoing urgent lower-limb surgery randomly received either CSA (22 G Sprotte needle, 28 G nylon catheter) in group 1 or CSE (18 G Tuohy needle, 22 G epidural catheter and 25 G pencil-point needle) in group 2. An initial subarachnoid bolus of 2 ml of plain bupivacaine 0.5% was injected in both groups. Difficulties with the lumbar puncture or catheter insertion, the time required for performance of either technique and the onset of analgesia at T12 were documented. If analgesia did not reach T12 within 20 min, supplemental bupivacaine was injected either intrathecally or epidurally up to a maximum of 5 ml in the CSA group or 16 ml in the CSE group. RESULTS: The number of lumbar punctures (CSA: n = 1.8 +/- 1.5; CSE: n = 2.6 +/- 1.8; P = 0.05) and the incidence of technical problems (CSA: 13%, CSE: 47%; P = 0.012) was higher in the CSE group. In contrast to CSA, performance of CSE was more time consuming (CSA: 8 +/- 3 min, CSE: 15 +/- 8 min; P = 0.0003), and the total dose of local anaesthetics was higher in the CSE group (CSA: 3.2 +/- 1 ml, CSE: 9.7 +/- 5 ml; P < 0.0001). CONCLUSIONS: Because of the higher incidence of technical problems, more time was required for the performance of CSE. As a consequence, microcatheter CSA might be preferred over CSE in trauma patients.
RCT Entities:
UNLABELLED: In this prospective study we investigated the efficacy of microcatheter spinal anaesthesia in comparison with a combined spinal-epidural technique in traumapatients. METHODS: After institutional approval 60 patients undergoing urgent lower-limb surgery randomly received either CSA (22 G Sprotte needle, 28 G nylon catheter) in group 1 or CSE (18 G Tuohy needle, 22 G epidural catheter and 25 G pencil-point needle) in group 2. An initial subarachnoid bolus of 2 ml of plain bupivacaine 0.5% was injected in both groups. Difficulties with the lumbar puncture or catheter insertion, the time required for performance of either technique and the onset of analgesia at T12 were documented. If analgesia did not reach T12 within 20 min, supplemental bupivacaine was injected either intrathecally or epidurally up to a maximum of 5 ml in the CSA group or 16 ml in the CSE group. RESULTS: The number of lumbar punctures (CSA: n = 1.8 +/- 1.5; CSE: n = 2.6 +/- 1.8; P = 0.05) and the incidence of technical problems (CSA: 13%, CSE: 47%; P = 0.012) was higher in the CSE group. In contrast to CSA, performance of CSE was more time consuming (CSA: 8 +/- 3 min, CSE: 15 +/- 8 min; P = 0.0003), and the total dose of local anaesthetics was higher in the CSE group (CSA: 3.2 +/- 1 ml, CSE: 9.7 +/- 5 ml; P < 0.0001). CONCLUSIONS: Because of the higher incidence of technical problems, more time was required for the performance of CSE. As a consequence, microcatheter CSA might be preferred over CSE in traumapatients.
Authors: Ingrid Arevalo-Rodriguez; Luis Muñoz; Natalia Godoy-Casasbuenas; Agustín Ciapponi; Jimmy J Arevalo; Sabine Boogaard; Marta Roqué I Figuls Journal: Cochrane Database Syst Rev Date: 2017-04-07