Angiographic follow-up and clinical experience with the flexible Tantalum Cordis stent.

P S Watson1, C K Ponde, C N Aroney, J Cameron, A Cannon, M Dooris, P J Garrahy, P T McEniery, J H Bett.   

Abstract

The Cordis stent is a flexible, highly radioopaque intracoronary stent engineered from a single Tantalum filament folded into a sinusoidal helical coil. It is premounted on a semicompliant balloon expandable stent delivery system. From September 1995-March 1996, 147 Cordis stents were deployed in 105 patients (aged 58+/-12 yr, 71% male). Clinical indications for stenting were unstable angina in 59 (55%), stable angina in 41 (38%), and acute myocardial infarction in 7 (7%). The target vessel was the right coronary artery in 45%, the left anterior descending in 31%, and the circumflex artery in 22%. One stent was deployed in a vein graft, and one stent was deployed in a left internal mammary artery graft. Stent deployment was achieved in all but one patient. Acute in-stent thrombosis occurred in 3 patients (2.9%). Two of these patients required urgent coronary artery bypass surgery. Subacute stent thrombosis occurred in 2 patients (1.9%). Minimum lumen diameter increased from 0.70+/-0.41 mm to 3.50+/-0.60 mm following stent placement. All patients received aspirin. Eighty-one patients (77%) received ticlopidine, and 4 patients (4%) received warfarin therapy. The mean hospital stay was 3.4+/-2.3 days. Six-month follow-up angiography was performed on 50 out of 55 eligible patients at one of the two institutions involved in this study. Computer-assisted quantitative coronary angiography defined a restenosis rate of 26%. Repeat revascularization was required in 8 patients (14.5%) at 6-mo follow-up. The Tantalum Cordis intracoronary stent is an effective and safe means of treating coronary lesions, even in patients with unstable ischemic syndromes. Acute and subacute rates of in-stent thrombosis were acceptable, and the long-term angiographic restenosis rates and need for repeat revascularization were favorable.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 9488549     DOI: 10.1002/(sici)1097-0304(199802)43:2<168::aid-ccd12>3.0.co;2-k

Source DB:  PubMed          Journal:  Cathet Cardiovasc Diagn        ISSN: 0098-6569


  1 in total

1.  Biological characteristics of the MG-63 human osteosarcoma cells on composite tantalum carbide/amorphous carbon films.

Authors:  Yin-Yu Chang; Heng-Li Huang; Ya-Chi Chen; Jui-Ting Hsu; Tzong-Ming Shieh; Ming-Tzu Tsai
Journal:  PLoS One       Date:  2014-04-23       Impact factor: 3.240

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.